Page 37
6.3
Water Supply (For Operation with Tap Water
or Partially/Fully Softened Water)
»
Install a shut-off valve (SV) in the supply line.
»
Install a water filter (WF) if water quality requires it.
»
Make sure that a backflow preventer is installed in the
water supply line.
Note:
Shut-off valve (SV) and water filter (WF) are not supplied
with the unit
»
HygroMatik provides a water hose (56) with a cap nut at
both ends which can be used for water installation.
Install as follows:
»
Screw and tighten the cap nut with its inner seal ring
around the water supply screw connection that pro-
trudes from the base.
Note:
Tightening too much will destroy the fitting. The valve
strainer (29) must be placed inside the solenoid valve.
»
Use a cap nut (internal thread ¾“) with inner seal for a
customer-provided water installation.
Water supply:
1bar min., 10bar max./
14.5psi min., 145psi max.