Heater-Related Messages
will begin again after about 1 min. See “Flow Related Checks” below
.
been disabled. See “Flow Related Checks” below. After the problem has been resolved, you must press any button to reset
and begin heater start up.
reset the heater start-up. See “Flow Related Checks” below.
Heater Flow is Reduced (LF)* – M017
There is not enough water ow through the heater to carry the heat away from the heating element and the heater has
Heater Flow is Reduced (HFL) – M016
There may not be enough water ow through the heater to carry the heat away from the heating element. Heater start up
Heater may be Dry (dr)* – M028
Possible dry heater, or not enough water in the heater to start it. The spa is shut down for 15 min. Press any button to
press any button to reset and restart heater start up. See “Flow Related Checks” below.
button to reset when water is below 108°f (42.2°C). See “Flow Related Checks” below.
Heater is Dry* – M027
There is not enough water in the heater to start it. The spa is shut down. After the problem has been resolved, you must
Heater is too Hot (OHH)* – M030
One of the water temp sensors has detected 118°f (47.8°C) in the heater and the spa is shut down. You must press any
A Reset Message may Appear with other Messages.
Some errors may require power to be removed and restored.
* This message can be reset from the topside panel with any button press.
Flow-Related Checks
Check for low water level, suction ow restrictions, closed valves, trapped air, too many closed jets and pump prime.
On some systems even when spa is shut down, some equipment may occasionally
turn on to continue monitoring temperature or if freeze protection is needed.
SPASIDE MESSAGES
35
Содержание 8800 BP Series
Страница 49: ......
Страница 50: ......
Страница 51: ......
Страница 52: ...85 0077 BP Rev 10 02 18...