18” Above
Maximum Water
Level
Check Valve*
Water
Level
Below
Water
Level
Above
Check*
Valve
To
Blower
CAUTION: The air blower must be connected ONLY to the
spa’s air distribution plumbing. Connecting the air blower to the
air piping associated with the hydrotherapy jets will create a
hazzard by providing a path for high-pressure water to be
forced into the blower motor. This will result in damage to the air
blower, and create an electrical shock hazzard.
Ÿ
The air blower must be installed to ensure that water
cannot enter the air blower motor. This can be
accomplished by installing a single or double air loop that
incorporates a check valve.
AIR BLOWER INSTALLATION (Optional)
SYSTEM CONFIGURATION
Below are illustrations and instructions for converting the universal circuits of your control.
Hydro-Quip utilizes color coded connectors to help identify each circuit. Simply locate the
colored connector on the Neutral (white) wire from each component receptacle on the PCB.
Using the wiring diagram provided with each control (located inside of cover), remove the Neutral
connector from its Block 4 / Neutral position and reconnect to an empty position at the Block 2 /
Line 2 connection block. Once accomplished the conversion is complete, repeat these steps for
each component that operates on 240V.
PUMP 1
RED
PUMP 2
VIOLET
BLOWER
BLUE
OZONE
YELLOW
120V
Block 4
240V
Block 2
COMPONENT COLOR CODE
(2) Reinstall connector onto Block 2 connection
(1) Remove connector from Block 4 connection
WHT AC
RED AC
18
JASON LUGO
ANALU D.
This System was pre-configured by the manufacturer as follows:
Pump 1: 240V
Pump 3: 240V
Ozone: 120V
Pump 2: 240V
Blower: 240V
CHANGING CONFIGURATIONS