COMPONENT CONNECTION
The system is set up to have components hardwired to a terminal strip inside the upper enclosure.
Liquid tight conduit must be used on all externally added field connections exposed to the weather.
Route and connect the conduit to the knock-outs in the back of the lower box. The wires will then
enter the bottom of the upper box through another set of knock-outs. Connect the component(s)
accordingly to the corresponding position on the terminal strip and tighten securely. Refer to the
included wiring diagram as needed. All components not included with the system are set at the
factory for 120V. Verify the voltage of the additional component(s) and adjust supply voltage if
necessary by referring to System Configuration on page 10.
LOWER BOX
LIQUID-TIGHT
CONDUIT
TO EXTERNAL
COMPONENT
BLOWER
GROUND
GROUND
GROUND
Lighting
Sanitation
Air Blower
Aux. Pump
Primary Pump
H L
C
L
C L
L
L
C
L
C
PUMP
1
PUMP
2
BLOWER
H L
C
OZONE
12V
LIGHT
L
C
PUMP
3
Aux. Pump
L
L
120V
LIGHT
FIREMANS
SWITCH
Lighting
FUSE 30A
FUSE 30A
J35
MAIN
MAIN
J34
UPPER BOX
15
*Systems equipped with blowers and Plus Ozone options come pre connected to the terminal strip
™