6
ELECTRICAL INSTALLATION
NOTICE! Before attempting installation of this equipment system, read all the
information contained in this manual, and confirm the installing electrician understands
and follows all national and local codes and safety instructions.
All connections must be made by a qualified and licensed electrician in accordance with
the National Electrical Code (NEC article 680 Canadian Electric Code, and with any local
codes in effect at the time of installation.
All connections must be made according to the electrical installation label on the outside
of the system box (see page 33) Follow all instructions provided in this manual, and at
labeled connections. If your electrician in unclear on how to correctly connect this
equipment, call your system supplier. Note that damage caused by mistakes can be
costly, and invalidate your warranty.
A GFCI (Ground fault circuit interrupter) breaker is a mandatory electrical device required
for installation on all pool/spa applications as specified in the National Electrical Code
Article 680-42.
The GFCI must be properly sized, and be connected with the appropriate sized wire per
NEC Code Table 310-16. All ground wires must be connected per NEC Table 250-122
Follow the instructions provided in this manual (see pages 7-9) for proper location and
connection of this safety device
This equipment requires a dedicated electrical supply circuit, with no other appliances or
lights connected.
IMPORTANT – The NEC and most local codes require that an electrical “disconnect” be
installed within “line of site” of the spa
Use copper conductors only, with grounding wire properly sized per the National Electric
Code table 250-95.
A bonding lug has been provided on the control box, allowing connection to local ground
points. To reduce the risk of electrical shock, use only a properly sized copper bonding
wire from this lug to all metal ladders, water pipes and other metallic objects within 5 feet
of the spa/hot tubs edge.
CAUTION:
Damage may occur to the circuit board and spaside if the spaside
plug is not properly aligned to the receptacle on the circuit board or if the
spaside plug is connected or disconnected while the power is on.
**Any resulting damages are not covered under manufacturer’s warranty**
CAUTION:
Do not connect or disconnect any components while the power is on.
All connections must be done with the power off as it may cause damage to the
system.
**Any resulting damages are not covered under manufacturer’s warranty**