TROUBLESHOOTING
PUMP STOPS DURING TIMED CYCLE
Motor overheat protection has tripped, allow motor to cool before reactivating
If motor continues to overheat, have an electrician check voltage and connections.
PUMP SURGES OR LOSES PRIME
Check for low water level, loose lid on pump, pipe leaks on suction plumbing, debris in
lter or suction ttings
PUMP MAKES CAVITATION OR “GRAVEL” SOUNDS
Check lter and baskets for debris overload
Check gate valves for full open position
Pump not having baskets or lters removed could clog pump impeller. contact your
installer.
PUMP DOESN’T STOP AFTER FILTER OR JET CYCLE
Pump will continue to run in low speed, if the water is not at the set temperature.
See “standard mode” in operations manual.
If lter cycle programs are overlapped, see operations manual
When freezing weather protection is activated. See “ICE” in operations manual
Main system pump #1 will operate once an hour for a few minutes to sample the
spa/hot tubs vessel temperature.
BLOWER DOESN'T START
Conrm operational command on spaside. Have installer review wire connection and
test fuse.
BLOWER TRIPS GFCI
Blower internals could be wet. Make sure device was placed above water level
and/or incorporates a loop per the installation instructions, so water cannot reach
motor. If motor is conrmed dry and continues to trip GFCI, contact your installer.
BLOWER RUNS, NO AIR
Make sure all blower plumbing is connected, and there is no ice formed in the lines.
The blower will not clear long distance pipes holding too much water. Conrm a
plumbing loop was installed near the spa per the assembly instructions
Conrm correct voltage has been supplied to blower, if added to system. If problem
continues call your installer