Plus Ozone Option
Systems equipped with the factory installed Plus Ozone™ option are identied with both a visible
green label on the front access door “A” and a generator connection barb extending from the
cabinet bottom. Follow these instructions and diagram to properly connect or disable the Plus
Ozone™ feature
*Refer to diagram #1 below for all locations for this section
8000 ES/CS Series outdoor control
ELECTRICAL CONNECTION:
The Plus Ozone™ generator comes prewired to the 8000 control system, there is no additional
electrical connection required
PLUMBING CONNECTION:
Locate the provided Ozone Check Valve Kit #48-0200 and follow the assembly diagram and
requirements for connecting check valve to tubing and ozone barb
ES SYSTEM WITH LOWER BASE CABINET
1. Select and remove ½” electrical knockout in lower cabinet for ozone tubing exit.
2. Install rubber grommet (provided) into hole for edge protection and insect block
3. Cut rubber grommet center skin open and feed tubing through hole
Your spa manufacturer will provide instructions for connecting the check valve to the spas ozone
vacuum plumbing.
NOTE: This Check valve can only be connected to an air vacuum plumbing
DO NOT connect to pressurized water pipes
20