LIGHT NOT WORKING
Conrm operational command on spaside. Light installed should be 120v. unless
installer used 12v light, and reprogrammed board wiring and logic using this manual
Make sure the bulb is in the correct position in the light assy. Contact your installer or
electrician to conrm wire connection, bulb operation, and light fuse
OZONE NOT WORKING
The ozone circuit will only work when the main pump #1 is in low speed operation.
Conrm with ozone suppliers operations manual for appliance testing. Ozone
circuit supply voltage is factory set at 115V (unless altered), test for correct supply
voltage for ozonator.
NO HEAT
Main pump must be on and pumping water for heater to operate. Low water levels,
dirty lters, or loss of prime will cause the pump to surge, and heater will not function
Conrm the heat light is on the spaside. And there is no error code message on
spaside. Spas heat slowly, so allow the system to run several hours before testing for
temperature rise.
On some system the heater is not allowed to operate when 2 or more pumps are
operating. Reference setup in this manual for programming changes, when power
supply allows.
NO HEAT (GAS HEATER)
Gas heaters have their own operating system, independent from the 8000 series
control. You must have the gas heaters thermostat set to “max” and the reman
electronic control wired to the 8000 system for proper control.
Refer to the gas heater hookup instruction in this guide for proper reman switch
connection, and consult the heater suppliers manual for all other operation and
troubleshooting
WATER NOT REACHING SET TEMPERATURE
Note that pump must be primed completely and running for heater to operate.
Additionally the system will not allow programmed temps above 104F.
Conrm heat indicator is on spaside display
Spaside should be programmed for a higher temp than current water temp., and in
“Standard Mode” see operations manual.
Check for heating error codes on spaside display and follow instructions
If heater is on its own GFCI breaker, check for tripped condition and reset
Consult gas heater manual for correct thermostat setting to work with 8000 series
Burned out elements are rare, but if all conditions for the heater have been checked,
consult an electrician for power supply problems, and heater element operation