Machine Maintenance
-
5-20
Steamatic 8800 TMU
To freeze guard the hoses and wand, perform Step 6 in the preceding procedure
with the items to be freeze guarded attached.
Always check the freezing level of your reclaimed antifreeze with a glycol tester
before reusing. failure to do so may result in serious component damage.
recovering antifreeze for re-use
Attach all hoses and wands which have been freeze guarded to the truckmount.
1.
Attach the incoming water source to the front of the truckmount.
2.
Start the truckmount.
3.
Spray the solution through the hoses and wands into a sealable container until all
4.
signs of antifreeze are gone.
freeze protection of the pump-In System
Drain the fresh water tank.
1.
Remove the garden hose adapter from the pump-in pump hose and position the
2.
hose so it is pointing outside the van.
Turn on the pump-in pump and run for 1 - 2 minutes until all the water is purged from
3.
the hose.
The next time the truckmount is used, it may take a few minutes before the water
box begins to fill.