5-3 - Machine Maintenance
Steamatic 8800 TMU
Quarterly maintenance
Check the fuel lines. Repair or replace as needed.
•
Clean and gap the spark plugs to 0.031 - 0.035” (0.8 - 0.9 mm). Replace if excessive
•
carbon buildup is visible.
Change the blower oil after first 100 hours of use.
•
500 Hours
Change the blower oil.
•
Change the high pressure pump oil.
•
Check the engine valve clearance (intake and exhaust 0.012” [0.30 mm])
•
Replace spark plugs
•
Change primary fuel filter
•
Change coolant
•
1,000 Hours
Replace spark plugs
•
Change primary air filter
•
flush coolant system
•