REPLACING THE SLIDE ACTUATOR
HT-044PS/HT-045PS/HT-245PS
REMOVING THE SLIDE ACTUATOR
December 15, 2011
It is imperative that Human Touch
®
products are repaired in a manner that ensures product safety and regulatory compliance and that is fully consistent with the practices used
during the manufacturing process. Therefore, Human Touch requires that all product repairs are performed using only factory-new parts and in accordance with these repair
instructions. Failure to adhere to these instructions voids the product warranty and releases Human Touch from all liability for injury or product damage resulting from the repair.
SERVICE LEVEL: 2
Tools Required:
Phillips-head screwdriver, small flat-head screwdriver.
NOTE:
SAVE ALL SCREWS FOR USE DURING REASSEMBLY.
1
1. Power off the chair, then unplug it.
2. Remove the seat cushion from the chair (Fig.1).
3. Lift the seat support to expose the slide actuator (Fig.2).
4. Using a Phillips-head screwdriver, remove the two screws from the connector junction box (Fig.3).
5. Remove the junction box cover, then disconnect the slide actuator connector (Fig.4).
(Fig.1)
Seat cushion
Seat
Connector
junction box
Slide actuator
connector
Slide actuator
(Fig.2)
(Fig.3)
(Fig.4)