4.6.3 Diagnosing MBTS Faults
In the case of GBTS/NodeB board alarms, GBTS/NodeB E1T1 alarms, and GBTS/NodeB
antenna alarms, if the causes of the fault cannot be located in the alarm information, you can
perform fault diagnosis and then take corresponding measures to handle the alarms.
Prerequisite
The automatic software commissioning already starts, and you have not confirmed the
completion of the commissioning yet.
Context
CAUTION
E1T1 fault diagnosis leads to the interruption of all services on the port; antenna fault diagnosis
leads to the interruption of all carrier services of the GBTS. Therefore, you need to perform the
fault diagnosis when the GBTS services are in idle state or are segregated.
l
After the fault diagnosis starts, the M2000 creates a diagnosis task and displays the
troubleshooting progress. After the fault diagnosis is complete, you can obtain the fault
diagnosis report to view fault location information.
l
If you delete a fault diagnosis task, the corresponding diagnosis report is deleted
accordingly. If you restart the M2000 server, all fault diagnosis tasks and reports are deleted.
Procedure
Step 1
Choose
Configuration
>
Auto Deployment
>
MBTS Auto Deployment
. The
MBTS Auto
Deployment
window is displayed.
Step 2
From
MBTS List
, select an MBTS whose alarms you need to view, and then click
on the
toolbar. The alarm monitoring window is displayed.
For details about the alarm monitoring window, see
Step 3
Perform fault analysis on board alarms, E1T1 alarms, and antenna alarms.
1.
Select an object (board, E1/T1, or antenna) in the left pane of the alarm monitoring window,
or select a specific alarm of an object (board, E1/T1, or antenna) from the alarm list in the
right pane.
2.
Right-click the selected object or alarm, and then choose
Diagnose
from the shortcut menu.
In the displayed dialog box, select the diagnosis type, enter the diagnosis parameters, and
then click
OK
. The M2000 starts the fault diagnosis.
A new diagnosis task is added to the diagnosis list. The diagnosis task list is located in the
lower part of the alarm monitoring window.
3.
In the diagnosis task list, right-click a fault diagnosis task, and then choose
Details
or
Diagnosis Report
from the shortcut menu. Then, view the diagnosis details or conclusion.
----End
3900 Series Multi-Mode Base Station
Commissioning Guide
4 Commissioning the MBTS in GU Mode on the M2000
Issue 02 (2010-07-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
4-19