Procedure
Step 1
Open the eNodeB commissioning report and view the health check report. Learn the running
status of the eNodeB.
Step 2
If the result of the eNodeB health check fails, check for active alarms and rectify the related
faults by referring to the
eNodeB Alarm Reference
. If all active alarms are cleared but the health
check still fails, contact Huawei for technical support.
----End
5.10 Testing the Basic Services of the eNodeB
This section describes how to test the basic services of the eNodeB.
Prerequisite
l
The eNodeB and the MME/S-GW are properly connected.
l
The negotiation data of the eNodeB to be commissioned is added to the MME/S-GW.
l
The testing UE is functional and is registered in the HSS.
l
The FTP server for testing the basic services is available.
l
The WWW server for testing the basic services is available.
Procedure
l
Test the web page browsing service.
Testing Method
Access the WWW server and browse the web pages through a UE.
Perform the test 20 times.
Expectation
Success rate > 95%. Web browsing is normal.
l
Test the file uploading service.
Testing Method
Access the FTP server and upload files through a UE. Perform the
test 10 times.
Expectation
Success rate > 90%. The upload rate is stable.
l
Test the file downloading service.
Testing Method
Access the FTP server and download files through a UE. Perform the
test 10 times.
Expectation
Success rate >90%. The download rate is stable.
l
Test the VoIP services.
Testing Method
Use the testing UE to call another UE 20 times.