Figure 7-3
Communication failed dialog box
Step 2
Click
Yes
.
The
Set Communication Port Parameter
dialog box is displayed, as shown in
.
Figure 7-4
Set Communication Port Parameter dialog box
Step 3
In the
Select Communication Port
area, click
Network Port
. In the
Configure IP
area, set the
IP address to
192.168.0.72
.
Step 4
Click
OK
.
Step 5
In the
Site Maintenance Terminal System
window, click
User
, and select
User Login
. Enter
User Name
(Omc by default) and
User Password
(omc by default).
----End
7.3 Configuring the Basic Data of the GBTS
This section describes how to configure the basic data of the GBTS such as the GBTS boards
and logical objects. You must configure the basic data of the GBTS before performing the local
commissioning on the GBTS side.
3900 Series Multi-Mode Base Station
Commissioning Guide
7 Commissioning the MBTS by Using Local Maintenance
Terminal and M2000