NOTE
l
Different devices must correspond to different IP addresses.
l
The IP addresses on the same network segment correspond to the same subnet masks and subnet addresses
(subnet mask AND IP address).
Step 3
Run
ping target_name -t
in the command window to check the connection between the LMT
client and the NodeB. "target_name" is the OM IP address of the base station.
----End
7.5.3 Logging In to the LMT
This section describes how to log in to the NodeB LMT.
Prerequisite
The communication between the LMT client and the NodeB is normal.
Procedure
Step 1
Choose
Start
>
All Programs
>
HUAWEI Local Maintenance Terminal
. If the Local
Maintenance Terminal is started, choose
System
>
Logout
, or click
. The
User Login
dialog box is displayed, as shown in
Figure 7-29
User Login dialog box
describes the fields in the
User Login
dialog box.
Table 7-4
Fields in the User Login dialog box
Field
Description
User Name
Type the user name of the NodeB. By default,
the user name is admin. The user name is
mandatory and case-sensitive.
7 Commissioning the MBTS by Using Local Maintenance
Terminal and M2000
3900 Series Multi-Mode Base Station
Commissioning Guide
7-34
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 02 (2010-07-30)