Shenzhen Hpmont Technology Co., Ltd.
Chapter 7 Elevator Application Guidance
HD5L Series Controller User Manual V1.4
―
87
―
7.3
Terminal Analogue Run Application
The elevator controller can calculate the motor present running direction (digital) and running speed
(analogue) according to the elevator control logic and send them to HD5L. HD5L control the motor to
run according to the controller’s command and speed.
Example:
A certain elevator with rated speed of 1.750m/s uses a drive in analogue run mode.
The brake and the running contactor are controlled by the elevator controller. The controller sends the
direction signal to HD5L in the form of digital and output the running speed to drive in the form of
analogue.
Use analogue weighing device and AI1 as analogue speed setting and AI2 as analogue weigh.
Control Part Connection
Figure 7-3 Terminal analogue running connection
Set Parameter
Refer to Table 7-1 for the general function code.
The terminal analogue special function code setting content is shown as Table 7-3.
Table 7-3 Terminal analogue run parameter
Ref. Code
Function
Value
Remark
F00.05
Operating mode
1
Terminal analogue control.
F02.02
Retention time of start zero-speed
0.5s
Adjust according the situation of
running contactor and brake at
motor start& stop.
F02.06
Retention time of stop zero-speed
0.5s
DI1
AI1
AI2
DI2
DI3
COM
RLY1
DO1
DO2
HD5L
Elevator
Controller
Controller enabled (EN)
UP
DN
Controller fault
Controller is running
Speed command
Weigh signal
PG feedback signal
Controller is at
zero-speed running
OUTA
OUTB
PB
PA
COM
Encoder
interface board
7