Chapter 5 Operation Instructions
Shenzhen Hpmont Technology Co., Ltd.
―
44
―
HD5L Series Controller User Manual V1.4
Upload and download parameters
Upload:
When F01.03 = 1, it uploads the setting value to the keypad. When the upload is finished, the keypad
will jump to display F01.00.
Download:
When F01.02 = 2, it downloads the setting value from the keypad. When the download is finished, the
keypad will jump to display F01.03.
The upload and download parameters are as shown in.
Figure 5-10 Display upload and download parameters
Note:
1. When downloading parameters, it displays “dFAiL” which means that the EEPROM storage parameters of
keypad do not match with function parameters of HD5L.
First, upload the setting value of the correct function code to the EEPROM of keypad, and then download.
2. When uploading / downloading parameters, it displays “E0022” (keypad EEPROM fault). It will jump to
next function code 10 seconds later. The troubleshooting is in Chapter 8 (on page 91).
5.3
Initial Power On
It needs carefully check before power is on. Please wire the controller according to the specifications
supplied by this manual.
After checking the wiring and mains supply voltage, switch on the circuit breaker and the controller
will be initialized. The keypad will display as shown in Figure 5-11.
Figure 5-11 Display initialing keypad
Para. being uploaded
Upload progress: 050%
=0 1.5 0 0 m/s
停机状态参数
Dnload fail
=0 1.5 0 0 m/s
ALM
STOP
UP
LO/RE
Para. being dnloaded
Dnload progress: 030%
=0 1.5 0 0 m/s
Hpmont Technology
Lu:
DC bus low
ALM
STOP
UP
LO/RE
Stop para.
Setting speed
= 1.5 0 0m/s
请按键以检测其有效性
ALM
STOP
UP
LO/RE