Chapter 6 Function Introduction
Shenzhen Hpmont Technology Co., Ltd.
―
74
―
HD5L Series Controller User Manual V1.4
6.2.17
F16: Function-boost Parameters
Ref. Code
Function Description
Setting Range [Default]
F16.00
Zero-speed running signal delay time
0.00 - 10.00 [0.30s]
Defines the delay time of HD5L from zero-speed run status to zero-speed run signal output.
F16.01
Zero-speed signal delay time
0.00 - 10.00 [0.30s]
Defines the delay time of HD5L from zero-speed status to zero-speed signal output.
F16.02
Current keep time after stop
0 - 9999 [300ms]
To eliminate the current noise of motor at stop, when the brake is finished, the cut-off run signal will reduce
the current to zero after the time of F16.02.
F16.03 Fan
control
mode
0 - 2 [0]
Defines the fan control mode. If there is overheat protection, the fan will run all the time.
0: Auto stop.
•
The fan runs all the time when HD5L is in run status. After HD5L stops for the time of F16.04, the fan
continues running if overheat protection is activated.
1: Immediately stop.
•
The fan runs all the time when HD5L is in running status, but stops when HD5L stops.
2: Run when power on.
•
The fan runs continuously after HD5L is switched on.
F16.04
Fan control delay time
0.0 - 600.0 [30.0s]
F16.05
Brake unit action voltage
380 - 750V [Depend on HD5L]
For 380V voltage class controller, the braking voltage range is 630 - 750V.
For 220V voltage class controller, the braking voltage range is 380 - 450V.
Note: The braking action enables only in run status of HD5L.
F16.06
Contactor fault detect time
0.1 - 10.0 [2.0s]
F16.07
Multi-speed inspection
0 - 7 [0]
When the DI terminals are not enough, the MS1 - MS3 can achieve the inspection run.
•
DI terminal = inspection terminal INS (No. 7 function), only need set F16.07 as 0 to enter terminal
inspection run.
•
DI terminals ≠ inspection terminal INS (No. 7 function), the MS1 - MS3 can achieve inspection run.
•
Value of MS1 - MS3 = value of F16.07, enter MS inspection run at MS run speed (F05.00 - F05.07).
Note: When MS run speed (F05.00 - F05.07) exceeds 0.630m/s, run at 0.630m/s.
F16.08
Zero-speed threshold
0.001 - 0.010 [0.003m/s]
When the present run speed ≤ F16.08, the system run speed will be condidered as 0. After zero-speed delay
signal, the zero-speed signal will output.
F16.09
Selection at motor overheat fault
0,1 [0]
0: When detect that the motor is overheated, alarms E0020 fault (motor overheat) after motor stops.
1: When detect that the motor is overheated, alarms E0020 fault (motor overheat) at once.
F16.10
The coefficient of frequency demultiplication of HD-PG11-SC-FD
1 - 256 [1]
To set the coefficient of frequency demultiplication of HD-PG11-SC-FD.
F16.11
Stationary auto-tuning and current limit of syn. motor
20 - 200 [120%]
F16.12
Delay time of run output signal
0.00 - 1.00 [0.00s]
Note: F16.12 is used to delay the controller running signal (output = No. 2 function) so as to control HD5L to open
the brake.