Shenzhen Hpmont Technology Co., Ltd.
Chapter 6 Function Introduction
HD5L Series Controller User Manual V1.4
―
57
―
6.2.6
F05: Speed Parameters
Ref. Code
Function Description
Setting Range [Default]
F05.00
Multi-speed 0
0.000 - F00.02 [0.000m/s]
F05.01
Multi-speed 1
0.000 - F00.02 [0.000m/s]
F05.02
Multi-speed 2
0.000 - F00.02 [0.000m/s]
F05.03
Multi-speed 3
0.000 - F00.02 [0.000m/s]
F05.04
Multi-speed 4
0.000 - F00.02 [0.000m/s]
F05.05
Multi-speed 5
0.000 - F00.02 [0.000m/s]
F05.06
Multi-speed 6
0.000 - F00.02 [0.000m/s]
F05.07
Multi-speed 7
0.000 - F00.02 [0.000m/s]
F05.00 - F05.07 define the MS running speed which use in MS run mode.
•
F00.02 defines the rated speed of elevator.
F05.08
Inspection run speed
0.000 - 0.630
[
0.200m/s
]
Defines the running speed of elevator in the inspection mode.
F05.09
Battery driven run speed
0.000 - F00.02 [0.100m/s]
Defines the running speed of elevator in the battery driven run mode.
F05.10
Up forced speed switch detection value
0.0 - 100.0 (F00.02) [97.0%]
Defines the speed detection value at the forced switch
action.
•
After forced switch act, the running speed exceeds
speed switch detection value, and decelerates to F05.22
(creeping speed) according to F03.12 (abnormal Dec
speed).
•
Properly set F05.10 to avoid climbing elevator at
elevator up.
F05.11
Down forced speed switch detection value
0.0 - 100.0 (F00.02) [97.0%]
To avoid plunging elevator at elevator down. Refer to F05.10.
F05.12
FDT1
0.0 - 100.0 (F00.02) [90.0%]
F05.13
FDT2
0.0 - 100.0 (F00.02) [90.0%]
F05.14
FDT1 delay level
0.0 - 100.0 (F00.02) [1.0%]
F05.15
FDT2 delay level
0.0 - 100.0 (F00.02) [1.0%]
When running speed is lower than one speed (F05.12 +
F05.14) FL in the right figure, ON indicating signal will
output till the running speed is lower than F05.12.
•
Refer to parameter F05.12 and F05.14 about F05.13 and
F05.15.
Car
Up forced
speed switch
Shaft top space
Top floor
Contact board
F05.14
F05.12
FL
Elevator speed
Time
Time
DO
ON
ON
OFF
FL=F05.12+F05.14
6