Chapter 6 Function Introduction
Shenzhen Hpmont Technology Co., Ltd.
―
68
―
HD5L Series Controller User Manual V1.4
Ref. Code
Function Description
Setting Range [Default]
7: Inspection input (INS).
•
If enabled, elevator will do inspection running.
•
This signal, when used together with UP / DN (No. 2 or No. 3 function) command, can control the
elevator to go up or down during inspection.
8: Battery-driven input (BAT).
•
If enabled, elevator will enter battery-driven running status.
9: Contactor feedback input (CSM).
10: Brake feedback input (BSM).
11 - 14: Weighing signal input 1 - 4 (WD1 - WD4).
•
The switch weight signals can input through this terminal. Based on these signals, HD5L sets the torque
bias and starts the elevator stably.
•
Select among WD1 - WD4 according to the actual number of weighing devices and set the load of
switches based on F6.08 - F6.11 (DI weighing signal 1 - 4).
•
If many terminals are enabled, the max No. terminal will be enabled.
For example:
When WD1 and WD2 are enabled simultaneously, only WD2 is the valid one.
15: Motor overheat input (OH).
16: Fault reset input (RST).
•
When HD5L alarms fault, reset it by this terminal.
•
The function of RST terminal is the same as the
key.
17: Up forced speed input (UPF).
18: Down forced speed input (DNF).
19: Governor feedback input(OSG).
20 - 33: Unused.
34: External fault (EXT).
•
The fault signignal.
The fault signal of external equipment can be input through this terminal, so HD5L
can monitor that equipment and respond accordingly. HD5L alarms E0024 fault (external fault) when
receives the EXT signal.
F12.13
Filter time of multi-speed terminal
0.000 - 2.000 [0.010s]
Defines the MS filter time to make up for the time error of MS input terminals.
•
Change F12.13 according to the change asynchronous level of numbers of MS input terminals.
F12.14 Unused
F12.15 DO1
function
0 - 20 [2]
F12.16 DO2
function
0 - 20 [3]
F12.17 RLY1
function
0 - 20 [14]
F12.18
RLY2 (I/O board) function
0 - 20 [0]
F12.19
RLY3 (I/O board) function
0 - 20 [0]
F12.20
RLY4 (I/O board) function
0 - 20 [0]
0:
Unused.
1: Controller is ready.
•
Signal ON will output if HD5L has no fault.
2: Controller is running.
•
HD5L is in running status and outputs indicating signal.
3: Zero-speed running.
•
ON signal will output if output speed of HD5L is zero but HD5L is in run status.
4: Zero-speed.
•
ON signal will output if output speed of HD5L is zero.