Chapter 5
119
Tests and Error Messages
MaxiLife Test Sequence and Error Messages
Typical Diag Error Messages
Error!
CPU Socket
Processor
VRM
HP KAYAK XU
When the Processor and VRM
are correctly installed, the
“smiling icon” is shown on the
LCD status panel.
Processor
VRM
If the Processor has only been
partly inserted in the proces-
sor slot (opposite side to the
VRM), then the displayed mes-
sage will indicate a CPU
socket error.
Error!
Power CPU 1
E r r o r !
P o w e r s u p p l y
Error!
CPU Socket
Processor
VRM
If the Processor has only been
partly inserted in the proces-
sor slot (closest side to the
VRM), then the displayed mes-
sage will indicate a Power
CPU 1 error.
Processor
VRM
The Processor has not been
inserted correctly in the pro-
cessor slot. The displayed
message will indicate a CPU
socket error.
Processor
The Processor has been cor-
rectly installed in the proces-
sor slot. However, the VRM is
not installed. The displayed
message will indicate a Power
CPU 1 error.
Error!
Power CPU 1
There is no installed Proces-
sor. However, the VRM is cor-
rectly installed. The displayed
message will indicate a Power
error.
VRM
If one of the following fatal malfunctions occur, the displayed
message will indicate a BIOS error:
The BIOS no longer works.
There is no Flash.
Error!
BIOS
Содержание X Class 500/550MHz
Страница 6: ...6 Contents ...
Страница 8: ...8 Figures ...
Страница 15: ...15 1 System Overview ...
Страница 66: ...66 Chapter2 System Board Devices on the ISA Bus ...
Страница 96: ...96 Chapter3 Interface Boards and Mass Storage Drivers Connectors and Sockets ...
Страница 134: ...134 Chapter5 Tests and Error Messages Beep Codes ...
Страница 135: ...135 A Regulatory Information and Warranty ...
Страница 146: ...146 AppendixA Regulatory Information and Warranty HP Hardware Warranty ...