Appendix E
Event Codes
299
307
Critical
A temperature sensor on a controller
FRU detected an over-temperature
condition that caused the controller to
shut down.
• Check that the storage system’s
fans are running.
• Check that the ambient
temperature is not too warm. The
enclosure operating range is
41
°
F to 104
°
F (5
°
C to 40
°
C).
• Check for any obstructions to the
airflow.
• If none of the above explanations
apply, replace the controller FRU
that reported the error.
308
Informational
The default host port speed has
changed from 4 Gbit/sec to 2 Gbit/sec
because the controller module’s HIM
has a Broadcom PBC.
309
Informational
Normally when the Management
Controller is started, the IP data is
obtained from the SEEPROM where
it is persisted. If the system is unable
to write it to the SEEPROM the last
time it changed, a flag is set in flash
memory. This flag is set during
startup, and if set, this event is logged
and the IP data that is in flash
memory is used. The only time that
this would not be the correct IP data
would be if the controller board was
swapped and then whatever data is on
the board’s flash memory is used.
310
Informational
After a rescan, the controller
completed back-end discovery and
initialization of enclosure data.
313
Critical
An I/O module is down and will not
be automatically restarted. This only
applies when the other SC goes
down.
The SC needs service or
replacement.
TABLE E-1
Event Descriptions and Recommended Actions
(Continued)
Event
Code
Event Type
Description
Recommended Action
Содержание StorageWorks 2000fc
Страница 16: ...16 HP StorageWorks 2000 Family Modular Smart Array reference guide August 2008 ...
Страница 28: ...28 HP StorageWorks 2000 Family Modular Smart Array reference guide August 2008 ...
Страница 134: ...134 HP StorageWorks 2000 Family Modular Smart Array reference guide August 2008 ...
Страница 148: ...148 HP StorageWorks 2000 Family Modular Smart Array reference guide August 2008 ...
Страница 180: ...180 HP StorageWorks 2000 Family Modular Smart Array reference guide August 2008 ...
Страница 194: ...194 HP StorageWorks 2000 Family Modular Smart Array reference guide August 2008 ...
Страница 226: ...226 HP StorageWorks 2000 Family Modular Smart Array reference guide August 2008 ...
Страница 246: ...246 HP StorageWorks 2000 Family Modular Smart Array reference guide August 2008 ...
Страница 254: ...254 HP StorageWorks 2000 Family Modular Smart Array reference guide August 2008 ...
Страница 318: ...318 HP StorageWorks 2000 Family Modular Smart Array reference guide August 2008 ...
Страница 330: ...330 HP StorageWorks 2000 Family Modular Smart Array reference guide August 2008 ...