![HP StorageWorks 2000fc Скачать руководство пользователя страница 175](http://html.mh-extra.com/html/hp/storageworks-2000fc/storageworks-2000fc_reference-manual_156070175.webp)
Chapter 5
Monitoring System Status
175
To view disk drive information and error statistics:
1. Select Monitor > Statistics > Disk Error Stats.
2. Select the disk drive whose error statistics you want to view.
3. Click Show Disk Drive Error Statistics.
To clear the disk drive error data for the selected drive:
●
Click Clear Selected Disk Drive Error Statistics.
To clear the disk drive error data for all drives:
●
Click Clear All Disk Drive Error Statistics.
I/O Timeout Count
The number of times the drive accepted an I/O request
but did not complete it in the required amount of time.
Excessive timeouts can indicate potential device failure
(media retries or soft, recoverable errors)
No Response Count
The number of times the drive failed to respond to an I/O
request. A high value can indicate that the drive is too
busy to respond to further requests.
Spin-up Retries
The number of times the drive failed to start on power-up
or on a software request. Excessive spin-up retries can
indicate that a drive is close to failing.
Media Errors
The number of times the drive had to retry an I/O
operation because the media did not successfully
record/retrieve the data correctly.
Non Media Errors
The number of soft, recoverable errors that are not
associated with drive media.
Bad Block Reassignments
The number of block reassignments that have taken place
since the drive was shipped from the vendor. A large
number of reallocations in a short period of time could
indicate a serious condition.
Bad Block List Size
The number of blocks that have been deemed defective
either from the vendor or over time due to reallocation.
Field
Description
Содержание StorageWorks 2000fc
Страница 16: ...16 HP StorageWorks 2000 Family Modular Smart Array reference guide August 2008 ...
Страница 28: ...28 HP StorageWorks 2000 Family Modular Smart Array reference guide August 2008 ...
Страница 134: ...134 HP StorageWorks 2000 Family Modular Smart Array reference guide August 2008 ...
Страница 148: ...148 HP StorageWorks 2000 Family Modular Smart Array reference guide August 2008 ...
Страница 180: ...180 HP StorageWorks 2000 Family Modular Smart Array reference guide August 2008 ...
Страница 194: ...194 HP StorageWorks 2000 Family Modular Smart Array reference guide August 2008 ...
Страница 226: ...226 HP StorageWorks 2000 Family Modular Smart Array reference guide August 2008 ...
Страница 246: ...246 HP StorageWorks 2000 Family Modular Smart Array reference guide August 2008 ...
Страница 254: ...254 HP StorageWorks 2000 Family Modular Smart Array reference guide August 2008 ...
Страница 318: ...318 HP StorageWorks 2000 Family Modular Smart Array reference guide August 2008 ...
Страница 330: ...330 HP StorageWorks 2000 Family Modular Smart Array reference guide August 2008 ...