Appendix E
Event Codes
279
45
Informational
A communication failure has
occurred between the controller and
an EMP.
47
Informational
An error detected by the sensors has
been cleared.
48
Informational
The vdisk name has been changed.
49
Informational
A lengthy SCSI maintenance
command has completed.
52
Informational
Vdisk expansion has started.
This operation can take days to
complete.
53
Informational
or warning
This event is logged as informational
when a vdisk expansion has
completed or a RAID morph
operation is canceled by the user.
This event is logged as a warning if
the RAID morph operation fails.
55
Informational
A SMART event occurred on the
specified drive.
Impending drive failure. See “Disk
Drive Errors and Recommended
Actions” on page 300.
56
Informational
The Storage Controller has been
restarted.
58
Warning or
informational
A disk drive or other SCSI device
(such as an EMP) detected an error.
This event is logged as a warning for
serious errors such as parity or drive
hardware failure, and as
informational for other errors.
• For warning events that indicate
a disk drive is bad, replace that
drive module.
• For warning events that indicate
an expansion module is bad,
replace that expansion module.
59
Warning or
informational
The controller detected an error while
communicating with the specified
SCSI device. The error was detected
by the controller, not the disk. This
event is logged as a warning for
parity errors, and as informational for
other errors.
• For warning events that indicate
a disk drive is bad, replace that
drive module.
• For warning events that indicate
an expansion module is bad,
replace that expansion module.
TABLE E-1
Event Descriptions and Recommended Actions
(Continued)
Event
Code
Event Type
Description
Recommended Action
Содержание StorageWorks 2000fc
Страница 16: ...16 HP StorageWorks 2000 Family Modular Smart Array reference guide August 2008 ...
Страница 28: ...28 HP StorageWorks 2000 Family Modular Smart Array reference guide August 2008 ...
Страница 134: ...134 HP StorageWorks 2000 Family Modular Smart Array reference guide August 2008 ...
Страница 148: ...148 HP StorageWorks 2000 Family Modular Smart Array reference guide August 2008 ...
Страница 180: ...180 HP StorageWorks 2000 Family Modular Smart Array reference guide August 2008 ...
Страница 194: ...194 HP StorageWorks 2000 Family Modular Smart Array reference guide August 2008 ...
Страница 226: ...226 HP StorageWorks 2000 Family Modular Smart Array reference guide August 2008 ...
Страница 246: ...246 HP StorageWorks 2000 Family Modular Smart Array reference guide August 2008 ...
Страница 254: ...254 HP StorageWorks 2000 Family Modular Smart Array reference guide August 2008 ...
Страница 318: ...318 HP StorageWorks 2000 Family Modular Smart Array reference guide August 2008 ...
Страница 330: ...330 HP StorageWorks 2000 Family Modular Smart Array reference guide August 2008 ...