![HP StorageWorks 2000fc Скачать руководство пользователя страница 152](http://html.mh-extra.com/html/hp/storageworks-2000fc/storageworks-2000fc_reference-manual_156070152.webp)
152
HP StorageWorks 2000 Family Modular Smart Array reference guide • August 2008
Host Port Status
This section describes status information shown for host ports on Fibre Channel
(FC), iSCSI, or SAS controller modules.
FC Host Port Status
The Host Port Status page shows a graphical representation of the host ports on each
controller, including a color-coded status for each port.
Figure 5-1
FC Host Port Status Example
To display host port status information:
1. Select Monitor > Status > Advanced Settings > Host Port Status.
The status of each port is determined by the following color code:
■
Green – Host link is up
■
Red – Host link is down
■
White – Port is unused and does not contain an SFP
2. To view information about a specific port, click the port.
The selected port is outlined in blue.
Details in the lower part of the panel vary depending on the selected port's status.
Some values are assigned only when the host link is up. An asterisk (*) indicates a
value that will take effect after loop initialization.
■
Host Port Status Details – Selected controller and port number.
■
SFP Detect – SFP is present or not present. An SFP is used to connect the FC
host port through an FC cable to another FC device.
■
Receive Signal – Signal is present or not present.
■
Link Status – Link is up (active) or down (inactive).
■
Signal Detect – Signal is detected or no signal.
Содержание StorageWorks 2000fc
Страница 16: ...16 HP StorageWorks 2000 Family Modular Smart Array reference guide August 2008 ...
Страница 28: ...28 HP StorageWorks 2000 Family Modular Smart Array reference guide August 2008 ...
Страница 134: ...134 HP StorageWorks 2000 Family Modular Smart Array reference guide August 2008 ...
Страница 148: ...148 HP StorageWorks 2000 Family Modular Smart Array reference guide August 2008 ...
Страница 180: ...180 HP StorageWorks 2000 Family Modular Smart Array reference guide August 2008 ...
Страница 194: ...194 HP StorageWorks 2000 Family Modular Smart Array reference guide August 2008 ...
Страница 226: ...226 HP StorageWorks 2000 Family Modular Smart Array reference guide August 2008 ...
Страница 246: ...246 HP StorageWorks 2000 Family Modular Smart Array reference guide August 2008 ...
Страница 254: ...254 HP StorageWorks 2000 Family Modular Smart Array reference guide August 2008 ...
Страница 318: ...318 HP StorageWorks 2000 Family Modular Smart Array reference guide August 2008 ...
Страница 330: ...330 HP StorageWorks 2000 Family Modular Smart Array reference guide August 2008 ...