282
HP StorageWorks 2000 Family Modular Smart Array reference guide • August 2008
80
Informational
The controller has modified mode
parameters on one or more drives.
81
Informational
The current controller has unkilled
the partner controller. The other
controller will restart.
83
Informational
The partner controller is changing
state (shutting down or restarting).
84
Warning
In an active-active configuration, the
current controller has forced the
partner controller to fail over for the
specified reason.
Save the log files and review them
for other errors. A service
technician can determine errors
from the logs.
86
Informational
The FC host port or drive parameters
have been changed.
87
Warning
The mirrored configuration retrieved
by this controller from the partner
controller has bad cyclic redundancy
check (CRC). The local flash
configuration will be used instead.
The mirrored configuration is
corrupted. Configuration data on
the two controllers may be out of
sync. Clear configuration may be
needed to fully recover from this.
88
Warning
The mirrored configuration retrieved
by this controller from the partner
controller is corrupt. The local flash
configuration will be used instead.
The mirrored configuration is
corrupted. Configuration data on
the two controllers may be out of
sync. Clear configuration may be
needed to fully recover from this.
89
Warning
The mirrored configuration retrieved
by this controller from the partner
controller has a configuration level
that is too high for the firmware in
this controller to process. The local
flash configuration will be used
instead.
This likely indicates that the
current controller has down-level
firmware. Update the firmware on
the down-level controller. Both
controllers should have the same
firmware versions.
When the problem is fixed, event
20 is logged.
TABLE E-1
Event Descriptions and Recommended Actions
(Continued)
Event
Code
Event Type
Description
Recommended Action
Содержание StorageWorks 2000fc
Страница 16: ...16 HP StorageWorks 2000 Family Modular Smart Array reference guide August 2008 ...
Страница 28: ...28 HP StorageWorks 2000 Family Modular Smart Array reference guide August 2008 ...
Страница 134: ...134 HP StorageWorks 2000 Family Modular Smart Array reference guide August 2008 ...
Страница 148: ...148 HP StorageWorks 2000 Family Modular Smart Array reference guide August 2008 ...
Страница 180: ...180 HP StorageWorks 2000 Family Modular Smart Array reference guide August 2008 ...
Страница 194: ...194 HP StorageWorks 2000 Family Modular Smart Array reference guide August 2008 ...
Страница 226: ...226 HP StorageWorks 2000 Family Modular Smart Array reference guide August 2008 ...
Страница 246: ...246 HP StorageWorks 2000 Family Modular Smart Array reference guide August 2008 ...
Страница 254: ...254 HP StorageWorks 2000 Family Modular Smart Array reference guide August 2008 ...
Страница 318: ...318 HP StorageWorks 2000 Family Modular Smart Array reference guide August 2008 ...
Страница 330: ...330 HP StorageWorks 2000 Family Modular Smart Array reference guide August 2008 ...