Programming the Enhanced Monitor
99
Chapter 3
STATus:QUEStionable:BLOWer:SPEed?
<blower>[,MIN|MAX]
The
STATus:QUEStionable:BLOWer:SPEed?
query returns an integer representing
the present fan speed in revolutions per minute (RPM).
Parameters
Returned Data
Comments
•
All fans operate at the same levels as a percentage of their full scale
(
STAT:QUES:BLOW:LEV?
returns that level). However, the power supply fans
operate at higher speeds than the mainframe cooling fan. The measurement
returned is the last measurement made on the fans. This should be within the
last 2 seconds. If the power of the mainframe is off, this query will return the
last measurement made before power turned off.
Reset Condition
*RST does not affect the fan speed directly. If the fans were on full speed because
the S
YSTem:BLOWer:STATE FULL
command had been executed, then *RST clears
that state to VARiable
Related
Commands
STATus:QUEStionable:BLOWer:LEVel?
Name
Type
Range
Default
Description
<
blower>
enum. BLOWer1,
BLOWer2,
BLOWer3
none
Indicates which fan speed is being queried.
BLOWer1 is the main cooling fan, BLOWer2 is
the Power Supply cooling fan, BLOWer3 is a
second Power Supply cooling fan on the HP
E8404A mainframes.
optional
parameter
enum
MIN
MAX
When used, returns maximum or minimum
RPM for the present fan level.
Type
Range
Description
int16
0 - 3500
The last measured fan speed, given in RPM.
Содержание E8402A
Страница 8: ...10 Contents ...
Страница 12: ...14 Notes ...
Страница 14: ......
Страница 26: ...28 Getting Started Chapter 1 ...
Страница 42: ...44 Using the Enhanced Monitor Chapter 2 ...
Страница 214: ...216 Servicing Your Mainframe Chapter 5 ...
Страница 226: ...228 HP E8402 E8404A Product Specifications Appendix A ...