Programming the Enhanced Monitor
Chapter 3
HISTory:RESet[:ALL]
HISTory:RESet:BLOWer [<
blower
>]
HISTory:RESet:CURRent [<
supply
>]
HISTory:RESet:POWer [<
supply
>]
HISTory:RESet:QUEue
HISTory:RESet:TEMPerature [<
slot
>]
HISTory:RESet:VOLTage [<
supply
>]
The
HISTory:RESet
commands erase all data being held by the HISTory subsystem:
histograms, minimum/maximum values, and the history queue. For example,
HIST:RES:ALL
erases all historical data;
HIST:RES:BLOW
erases the historical data
stored for the specified <blower>,
HIST:RES:CURR
erases the amperage historical
data for the specified <supply>, etc. The
HISTory:RESet
command does not erase
stripchart data. The following table describes the commands and their parameters.
These commands are not allowed while the mainframe’s power is off.
Parameters
Command
Parameter(s) Range Default
Description
[:ALL]
Erases all historical data. The history queue retains two entries
(ALL HISTORY RESET, and QUEUE RESET) marking the time
between manufacture and the HISTory:RESet. These commands
are not allowed while the mainframe’s power is off.
:BLOW <
blower>
BLOWer1,
BLOWer2,
BLOWer3
none
Selects the fan whose historical data is to be erased. BLOWer1 is
the main cooling fan, BLOWer2 is the Power Supply cooling fan,
BLOWer3 is a second Power Supply cooling fan on the HP
E8404A mainframes.
:CURR <
supply>
P5, P12, N12, P24,
N24, N5PT2, N2,
P5STby
none
Erases the amperage historical data for the selected <
supply>.
Selects the power supply whose historical data is to be zeroed.
P5 is positive 5 Vdc supply, N12 is negative 12 Vdc supply, etc.
:POW <
supply>
P5, P12, N12, P24,
N24, N5PT2, N2, TOTal
none
Erases the wattage historical data for the <
supply>. Selects the
power supply whose historical data is to be zeroed. P5 is
positive 5 Vdc supply, N12 is negative 12 Vdc supply, etc.
:QUE
Erases all the events stored in the history queue. One event is
put in the history queue on this command: an event logging the
time since manufacture of the mainframe until the
HIST:RES:QUE command. This is a completely destructive
command. There is no retrieving the history queue. It is primarily
needed if the history queue has filled up.
:TEMP <
slot>
OUT0…OUT12,
DELTa0…DELTa12,
AMBient
PSUPply
none
Absolute Slot Temperature Histogram
Delta Slot Temperature Histogram
Ambient Temperature Histogram
Power Supply Temperature Histogram
:VOLT <
supply>
P5, P12, N12, P24,
N24, N5PT2, N2
none
Erases the voltage historical data for the selected <
supply>.
P5 is positive 5 Vdc supply, N12 is negative 12 Vdc supply, etc.
Содержание E8402A
Страница 8: ...10 Contents ...
Страница 12: ...14 Notes ...
Страница 14: ......
Страница 26: ...28 Getting Started Chapter 1 ...
Страница 42: ...44 Using the Enhanced Monitor Chapter 2 ...
Страница 214: ...216 Servicing Your Mainframe Chapter 5 ...
Страница 226: ...228 HP E8402 E8404A Product Specifications Appendix A ...