76
Programming the Enhanced Monitor
Chapter 3
HISTory:TEMPerature:CMAXimum?
<
slot
>
HISTory:TEMPerature:CMINimum?
<
slot
>
HISTory:TEMPerature:CMAXimum?
<slot> returns a single floating point number
for the maximum temperature measured by the Enhanced Monitor for the <slot>
parameter since power-on of the mainframe.
HISTory:TEMPerature:CMINimum?
<slot> returns a single floating point number
for the minimum temperature measured by the Enhanced Monitor for the <slot>
parameter since power-on of the mainframe.
Parameters
Returned Data
Comments
•
These maximums/minimums can be reset by powering the mainframe off and
then powering it back on.
Error Conditions
The following table lists the most common error conditions and causes. Error
numbers and corresponding messages can be found using
SYSTem:ERRor?
query.
Reset Condition
A *RST has no effect on the HISTory subsystem.
Related
Commands
HISTory:TEMPerature:MAXimum?, HISTory:TEMPerature:MINimum?,
HISTory:TEMPerature:[HISTogram]?
Name
Type
Range
Default
Description
<
slot>
enum.
OUT0…OUT12,
DELTa0…DELTa12,
AMBient
none
Exhaust temperature for slots 0 - slot
12
Temperature change above the
ambient temperature for slots0 - slot
12
Entrance air temperature
Type
Range
Description
float
Minimum or maximum temperature.
Number
Message
Probable Cause
-109
“Missing parameter”
You must include the <
slot> parameter.
-224
“Illegal Parameter”
The
<slot> parameter was not correct.
Содержание E8402A
Страница 8: ...10 Contents ...
Страница 12: ...14 Notes ...
Страница 14: ......
Страница 26: ...28 Getting Started Chapter 1 ...
Страница 42: ...44 Using the Enhanced Monitor Chapter 2 ...
Страница 214: ...216 Servicing Your Mainframe Chapter 5 ...
Страница 226: ...228 HP E8402 E8404A Product Specifications Appendix A ...