Programming the Enhanced Monitor
77
Chapter 3
HISTory:TEMPerature[:HISTogram]?
<
slot
>[,MIN|MAX]
HISTory:TEMPerature[:HISTogram]?
<slot> returns the histogram data held for the
specified <slot>. Ten values are returned for the amount of time the <slot>’s
temperature spent in ten different temperature ranges. Those temperature ranges can
be queried with the MIN and MAX optional parameter. The units of the time values
returned are HOURs by default, but can be changed with the
HISTory:UNIT[:TIME]
command. The units returned for temperature ranges queried with the
MIN
or
MAX
parameters are an integer values in tenths of a degree Celsius (0.x
°
C).
Parameters
Returned Data
Comments
•
HIST:TEMP? OUT2
returns 10 time values for the exhaust temperature of slot
2, units set/queried by HIST:UNIT.
•
HIST:TEMP? OUT2,MAX
returns 10 temperatures that returns the maximums
for each temperature range in tenths of a degree Celsius (0.x
°
C) for slot 2.
Error Conditions
The following table lists the most common error conditions and causes. Error
numbers and corresponding messages can be found using
SYSTem:ERRor?
query.
Reset Condition
A *RST has no effect on the HISTory subsystem.
Related
Commands
HISTory:RESet:CURRent, HISTory:UNITs[:TIME]
Name
Type
Range
Default
Description
<
slot>
enum. OUT0…OUT12,
DELTa0…DELTa12,
AMBient
PSUPply
none
Absolute Slot Temperature
Delta Slot Temperature Histogram
Ambient Temperature Histogram
Power Supply Temperature
optional
parameter
enum. MIN, MAX
none
Returns the maximums or minimums
of the temperature ranges.
Type
Range
Default
Description
<range1>
int32
0-2147483647
none
lowest temperature range.
<range2>
int32
0-2147483647
none
second temperature range.
<range3>
int32
0-2147483647
none
third temperature range.
<range4>
int32
0-2147483647
none
fourth temperature range.
<range5>
int32
0-2147483647
none
fifth temperature range.
<range6>
int32
0-2147483647
none
sixth temperature range.
<range7>
int32
0-2147483647
none
seventh temperature range.
<range8>
int32
0-2147483647
none
eighth temperature range.
<range9>
int32
0-2147483647
none
ninth temperature range.
<range10>
int32
0-2147483647
none
highest temperature range.
Number
Message
Probable Cause
-109
“Missing Parameter”
The
<slot> parameter was omitted.
-224
“Illegal Parameter”
The
<slot> or optional parameter were not correct.
-311
“Memory error”
The historical data’s memory is not available.
Содержание E8402A
Страница 8: ...10 Contents ...
Страница 12: ...14 Notes ...
Страница 14: ......
Страница 26: ...28 Getting Started Chapter 1 ...
Страница 42: ...44 Using the Enhanced Monitor Chapter 2 ...
Страница 214: ...216 Servicing Your Mainframe Chapter 5 ...
Страница 226: ...228 HP E8402 E8404A Product Specifications Appendix A ...