Environmental Specifications
Temperature
Operating Temperature Range:0
°
C to +55
°
C
Storage Temperature Range:-40
°
C to +75
°
C
Humidity
Operating Humidity Range:Up to 95% RH from 0
°
C to +40
°
C.
Up to 65% RH from +40
°
C to +55
°
C.
Storage Humidity Range: Up to 95% RH from 0
°
C to +55
°
C.
Up to 65% RH from +55
°
C to +75
°
.
Shock
End Use Handling:Half sine waveform, <3 msec Duration,
∆
v = 160 cm/sec minimum
Transportation:Trapezoidal waveform,
∆
v = 605 cm/sec,
30 g minimum
Vibration
Operating and Functional:5 to 500 Hz, 0.0001 g
2
/Hz Spectral Density
Survival, Swept Sine:5 to 500 Hz Resonance Search, 5 minute Dwell on
Resonances at 0.5 g
Survival, Random:0.015 g
2
/Hz Spectral Density
Altitude:Up to 3000m
Pollution Degree 2
Safety Specifications
Conforms to EN61010-1 including Amendment 2 (IEC 1010-1 including
Amendment 2)
Certified to CSA 1010.1
NRTL Listing to UL 3111-1
Certified to EN60950 (IEC 950)
Certified to CSA 950.
NRTL Listing to UL 1950 Compliance.
Electromagnetic
Compliance
Specifications
Conducted Emissions
Conforms to EN55011, CISPR11, Group 1 Class A
Conforms to EN61000-3-2, IEC 1000-3-2, Class A, Harmonic Current
Conforms to EN61000-3-3, IEC 1000-3-3, Class A, Voltage Fluctuations
and Flicker
Conducted Immunity
Conforms to EN50082-1, IEC 1000-4-4, Fast Transients Immunity
Conforms to EN61000-4-5, IEC 1000-4-5, Surge Immunity
Conforms to ENV50141, IEC 1000-4-6, Conducted Immunity
Conforms to EN61000-4-11, IEC 1000-4-11 Voltage Dips &
Interruptions
Содержание E8402A
Страница 8: ...10 Contents ...
Страница 12: ...14 Notes ...
Страница 14: ......
Страница 26: ...28 Getting Started Chapter 1 ...
Страница 42: ...44 Using the Enhanced Monitor Chapter 2 ...
Страница 214: ...216 Servicing Your Mainframe Chapter 5 ...
Страница 226: ...228 HP E8402 E8404A Product Specifications Appendix A ...