Fabric OS 6.2 administrator guide 335
Configuration scenarios
The actual number of virtual N_Port_IDs accepted per port and per switch is determined by the limits you
set, and also by the limit that is reached first.
For example, if you have set
switch.login.perPortMax
to 25, and
switch.login.perSwitchMax
to 100, the first 4 ports will accept up to 25 virtual N_Port_IDs each.
However, the fifth port will reject any more virtual N_Port_IDs because the
switch.login.perSwitchMax
parameter (100) has been reached.
If you set
switch.login.perPortMax
to 50, and
switch.login.perSwitchMax
to 25, the first
port requests 50 virtual N_Port_IDs; 25 are accepted, and 25 are rejected. The second port requests 50
virtual N_Port_IDs, but none are accepted, because the
switch.login.perSwitchMax
limit of 25 has
been reached.
Viewing NPIV port configuration information
To view the NPIV capability of switch ports, enter the
portCfgShow
command.
1.
Connect to the switch and log in using an account assigned to the admin role.
2.
Enter the
portCfgShow
command to view the switch ports information.
Alternatively, you can enter the
switchShow
command to view the WWN of an N_Port,
or
Enter the
portShow
command to view the N_Port attributes.
The following example shows whether or not a port is configured for NPIV:
switch:admin>
portcfgshow
Ports of Slot 0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
-----------------+--+--+--+--+----+--+--+--+----+--+--+--+----+--+--+--
Speed AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN
Trunk Port ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON
Long Distance .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
VC Link Init .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
Locked L_Port .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
Locked G_Port .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
Disabled E_Port .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
ISL R_RDY Mode .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
RSCN Suppressed .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
Persistent Disable.. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
NPIV capability ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON
Use the
switchShow
and
portShow
commands to view NPIV information for a given port. If a port is an
F_Port, and you enter the
switchShow
command, the port WWN of the N_Port is returned. For an NPIV
F_Port, there are multiple N_Ports, each with a different port WWN. The
switchShow
command output
indicates whether or not a port is an NPIV F_Port, and identifies the number of virtual N_Ports behind it.
The following is sample output from the
switchShow
command:
switch: admin>
switchshow
switchName:swd77
switchType:32.0
switchState: Online
switchMode:Native
switchRole:Principal
switchDomain: 99
switchId:fffc63
switchWwn:10:00:00:05:1e:35:37:40
zoning: OFF
switchBeacon:OFF
Area Port Media Speed State
==============================
Содержание A7533A - Brocade 4Gb SAN Switch Base
Страница 1: ...HP StorageWorks Fabric OS 6 2 administrator guide Part number 5697 0016 Edition May 2009 ...
Страница 24: ...24 ...
Страница 99: ...Fabric OS 6 2 administrator guide 99 ...
Страница 100: ...100 Managing user accounts ...
Страница 118: ...116 Configuring standard security features ...
Страница 164: ...162 Configuring advanced security features ...
Страница 234: ...232 Installing and maintaining firmware ...
Страница 268: ...266 Administering advanced zoning ...
Страница 284: ...282 Configuring Enterprise class platforms ...
Страница 292: ...290 Routing traffic ...
Страница 294: ...292 Interoperability for merged SANs ...
Страница 302: ...300 Configuring the Distributed Management Server ...
Страница 334: ...332 iSCSI gateway service ...
Страница 340: ...338 Administering NPIV ...
Страница 407: ...Fabric OS 6 2 administrator guide 405 ...
Страница 408: ...406 Using the FC FC routing service ...
Страница 438: ...434 Administering extended fabrics ...
Страница 460: ...456 Administering ISL trunking ...
Страница 498: ...494 Configuring and monitoring FCIP extension services 556200 Bps 30s avg 491394 Bps lifetime avg ...
Страница 516: ...512 FICON fabrics ...
Страница 526: ...522 Configuring and monitoring FICON Extension Services ...
Страница 540: ...536 Configuring the PID format ...
Страница 544: ...540 Understanding legacy password behavior ...
Страница 546: ...542 Mixed fabric configurations for non merge SANs ...
Страница 550: ...546 Migrating from an MP Router to a 400 MP Router ...
Страница 558: ...554 Inband Management ...
Страница 572: ...568 ...