528 Configuring the PID format
Changing the PID format
Whether it is best to perform an offline or online update depends on the uptime requirements of the site.
Following are some aspects of offline and online changes:
•
An offline update must have all devices attached to the fabric be offline.
•
With careful planning, it should be safe to update the core PID format parameter in a live, production
environment. This requires dual fabrics with multipathing software. Avoid running backups during the
update process, as tape drives tend to be very sensitive to I/O interruption. The online update process
is intended only for use in uptime-critical dual-fabric environments, with multipathing software
(high-uptime environments should always use a redundant fabric SAN architecture). Schedule a time for
the update when the least critical traffic is running.
All switches running any version of Fabric OS 3.1.2 and later or 4.2.0 and later are shipped with the Core
Switch PID format enabled, so it is not necessary to perform the PID format change on these switches.
Migrating from manual PID binding (such as persistent binding on an HBA) to manual WWN binding and
upgrading drivers to versions that do not bind by PID can often be done before setting the core PID format.
This reduces the number of variables in the update process.
Changing the PID format online
The following steps are intended to provide SAN administrators a starting point for creating site-specific
procedures.
1.
Back up all data and verify backups.
2.
Verify that the multipathing software can automatically switch over between fabrics seamlessly. If there
is doubt, use the software’s administrative tools to manually disassociate or mark offline all storage
devices on the first fabric to be updated.
3.
Verify that I/O continues over the other fabric.
4.
Disable all switches in the fabric to be updated, one switch at a time, and verify that I/O continues over
the other fabric after each switch disable.
5.
Change the PID format on each switch in the fabric.
6.
Re-enable the switches in the updated fabric one at a time. In a core/edge network, enable the core
switches first.
7.
After the fabric has reconverged, use the
cfgEnable
command to update zoning.
8.
Update the bindings for any devices manually bound by PID. This might involve changing them to the
new PIDs, or preferably changing to WWN binding.
For any devices automatically bound by PID, two options exist:
a.
Execute a custom procedure to rebuild its device tree online. Examples are provided in the ”
Port
number to area ID conversion
” on page 530 section of this chapter.
b.
Reboot the device to rebuild the device tree. Some operating systems require a special command to
do this, for example
boot –r
in Solaris.
9.
For devices that do not bind by PID or have had their PID binding updated, mark online or reassociate
the disk devices with the multipathing software and resume I/O over the updated fabric.
10.
Repeat with the other fabrics.
Changing the PID format offline
The following steps are intended to provide SAN administrators a starting point for creating site-specific
procedures.
1.
Schedule an outage for all devices attached to the fabric.
2.
Back up all data and verify backups.
3.
Shut down all hosts and storage devices attached to the fabric.
4.
Disable all switches in the fabric.
5.
Change the PID format on each switch in the fabric.
Содержание A7533A - Brocade 4Gb SAN Switch Base
Страница 1: ...HP StorageWorks Fabric OS 6 2 administrator guide Part number 5697 0016 Edition May 2009 ...
Страница 24: ...24 ...
Страница 99: ...Fabric OS 6 2 administrator guide 99 ...
Страница 100: ...100 Managing user accounts ...
Страница 118: ...116 Configuring standard security features ...
Страница 164: ...162 Configuring advanced security features ...
Страница 234: ...232 Installing and maintaining firmware ...
Страница 268: ...266 Administering advanced zoning ...
Страница 284: ...282 Configuring Enterprise class platforms ...
Страница 292: ...290 Routing traffic ...
Страница 294: ...292 Interoperability for merged SANs ...
Страница 302: ...300 Configuring the Distributed Management Server ...
Страница 334: ...332 iSCSI gateway service ...
Страница 340: ...338 Administering NPIV ...
Страница 407: ...Fabric OS 6 2 administrator guide 405 ...
Страница 408: ...406 Using the FC FC routing service ...
Страница 438: ...434 Administering extended fabrics ...
Страница 460: ...456 Administering ISL trunking ...
Страница 498: ...494 Configuring and monitoring FCIP extension services 556200 Bps 30s avg 491394 Bps lifetime avg ...
Страница 516: ...512 FICON fabrics ...
Страница 526: ...522 Configuring and monitoring FICON Extension Services ...
Страница 540: ...536 Configuring the PID format ...
Страница 544: ...540 Understanding legacy password behavior ...
Страница 546: ...542 Mixed fabric configurations for non merge SANs ...
Страница 550: ...546 Migrating from an MP Router to a 400 MP Router ...
Страница 558: ...554 Inband Management ...
Страница 572: ...568 ...