Fabric OS 6.2 administrator guide 527
• JBOD drive firmware versions
• Multipathing software versions
• HBA time-out values
• Multipathing software timeout values
• Kernel timeout values
• Configuration of switch
2.
Make a list of manually configurable PID drivers.
Some device drivers do not automatically bind by PID, but allow the operator to manually create a PID
binding. For example, persistent binding of PIDs to logical drives might be done in many HBA drivers.
Make a list of all devices that are configured this way. If manual PID binding is in use, consider
changing to WWN binding.
The following are some of the device types that might be manually configured to bind by PID:
• HBA drivers (persistent binding)
• RAID arrays (LUN access control)
• SCSI bridges (LUN mapping)
3.
Analyze data.
After you have determined the code versions of each device on the fabric, they must be evaluated to
find out if any automatically bind by PID. It might be easiest to work with the support providers of these
devices to get this information. If this is not possible, you might need to perform empirical testing.
Binding by PID can create management difficulties in a number of scenarios. HP recommends that you
not use drivers that bind by PID. If the current drivers do bind by PID, upgrade to WWN-binding drivers
if possible.
The drivers shipping by default with HP/UX and AIX bind by PID, and so detailed procedures are
provided for these operating systems in this chapter. Similar procedures can be developed for other
operating systems that run HBA drivers that bind by PID.
There is no inherent PID binding problem with either AIX or HP/UX. It is the HBA drivers shipping with
these operating systems that bind by PID. Both operating systems are expected to release HBA drivers
that bind by WWN, and these drivers might already be available through some support channels.
Work with the appropriate support provider to find out about driver availability.
It is also important to understand how multipathing software reacts when one of the two fabrics is taken
offline. If the time-outs are set correctly, the failover between fabrics should be transparent to the users.
You should use the multipathing software to manually fail a path before starting maintenance on that
fabric.
4.
Perform empirical testing.
Empirical testing might be required to determine whether some devices bind by PID. If you are not sure
about a device, work with the support provider to create a test environment.
Create as close a match as practical between the test environment and the production environment,
and perform an update using the procedure in ”
Changing the PID format online
” on page 528.
Devices that bind by PID are unable to adapt to the new format, and one of three approaches must be
taken with them:
• A plan can be created for working around the device driver’s limitations in such a way as to allow
an online update. See the Detailed Procedures section for examples of how this could be done.
• The device can be upgraded to drivers that do not bind by PID.
• Downtime can be scheduled to reset the device during the core PID update process, which generally
allows the mapping to be rebuilt.
If either of the first two options are used, the procedures should again be validated in the test
environment.
Determine the behavior of multipathing software, including but not limited to:
• HBA time-out values
• Multipathing software time-out values
• Kernel time-out values
Содержание A7533A - Brocade 4Gb SAN Switch Base
Страница 1: ...HP StorageWorks Fabric OS 6 2 administrator guide Part number 5697 0016 Edition May 2009 ...
Страница 24: ...24 ...
Страница 99: ...Fabric OS 6 2 administrator guide 99 ...
Страница 100: ...100 Managing user accounts ...
Страница 118: ...116 Configuring standard security features ...
Страница 164: ...162 Configuring advanced security features ...
Страница 234: ...232 Installing and maintaining firmware ...
Страница 268: ...266 Administering advanced zoning ...
Страница 284: ...282 Configuring Enterprise class platforms ...
Страница 292: ...290 Routing traffic ...
Страница 294: ...292 Interoperability for merged SANs ...
Страница 302: ...300 Configuring the Distributed Management Server ...
Страница 334: ...332 iSCSI gateway service ...
Страница 340: ...338 Administering NPIV ...
Страница 407: ...Fabric OS 6 2 administrator guide 405 ...
Страница 408: ...406 Using the FC FC routing service ...
Страница 438: ...434 Administering extended fabrics ...
Страница 460: ...456 Administering ISL trunking ...
Страница 498: ...494 Configuring and monitoring FCIP extension services 556200 Bps 30s avg 491394 Bps lifetime avg ...
Страница 516: ...512 FICON fabrics ...
Страница 526: ...522 Configuring and monitoring FICON Extension Services ...
Страница 540: ...536 Configuring the PID format ...
Страница 544: ...540 Understanding legacy password behavior ...
Страница 546: ...542 Mixed fabric configurations for non merge SANs ...
Страница 550: ...546 Migrating from an MP Router to a 400 MP Router ...
Страница 558: ...554 Inband Management ...
Страница 572: ...568 ...