Fabric OS 6.2 administrator guide 353
4.
Enter the
cfgEnable
command to reactivate your current effective configuration and enforce the TI
zones.
cfgenable "base_config"
For example, to create TI zones in the base fabric shown in
Figure 52
on page 349:
BS_D1>
zonecreate "z1", "1,1"
BS_D1>
cfgcreate "base_cfg", z1
BS_D1>
zone --create -t ti -o f "ti_zone2" -p "1,3; 1,10; 7,12; 7,14;
2,16; 2,8"
BS_D1>
cfgenable "base_config"
Modifying TI zones
Using the
zone
--
add
command, you can add ports to an existing TI zone, change the failover option, or
both.
Using the
zone
--
remove
command, you can remove ports from existing TI zones. If you remove the last
member of a TI zone, the TI zone is deleted.
After you modify the TI zone, you must enable the current effective configuration to enforce the changes.
IMPORTANT:
If failover is disabled, do not allocate all ISLs in TI zones. Make sure sufficient
non-dedicated paths exist through the fabric for all devices that are not in a TI zone. See ”
TI zone failover
”
on page 340 for additional information about disabling failover mode.
1.
Connect to the switch and log in as admin.
2.
Enter the
zone
--
add
command to add ports or change the failover option for an existing TI zone.
3.
Enter the
zone
--
remove
command to remove ports from an existing TI zone.
zone --add [-o
optlist
]
name
-p "
portlist
"
zone --add -o
optlist
name
[-p "
portlist
"]
zone --remove
name
-p "
portlist
"
where:
4.
Enter the
cfgEnable
command to reactivate your current effective configuration and enforce the TI
zones.
cfgenable "
current_effective_configuration
"
Examples of modifying a TI zone
To add port members to the existing TI zone bluezone:
switch:admin>
zone --add bluezone -p "3,4; 3,6"
optlist
The failover mode setting, which is either
n
or
f
.
•
n = Disable failover mode.
•
f = Enable failover mode.
Be aware of the ramifications if you disable failover mode. See ”
TI zone failover
”
on page 340 for information about disabling failover mode.
name
The name of the zone to be modified.
portlist
The list of ports to be added to or removed from the TI zone. Ports are designated
using “D,I” (Domain,Index) format. Multiple ports are separated by a semicolon,
followed by a space.
Содержание A7533A - Brocade 4Gb SAN Switch Base
Страница 1: ...HP StorageWorks Fabric OS 6 2 administrator guide Part number 5697 0016 Edition May 2009 ...
Страница 24: ...24 ...
Страница 99: ...Fabric OS 6 2 administrator guide 99 ...
Страница 100: ...100 Managing user accounts ...
Страница 118: ...116 Configuring standard security features ...
Страница 164: ...162 Configuring advanced security features ...
Страница 234: ...232 Installing and maintaining firmware ...
Страница 268: ...266 Administering advanced zoning ...
Страница 284: ...282 Configuring Enterprise class platforms ...
Страница 292: ...290 Routing traffic ...
Страница 294: ...292 Interoperability for merged SANs ...
Страница 302: ...300 Configuring the Distributed Management Server ...
Страница 334: ...332 iSCSI gateway service ...
Страница 340: ...338 Administering NPIV ...
Страница 407: ...Fabric OS 6 2 administrator guide 405 ...
Страница 408: ...406 Using the FC FC routing service ...
Страница 438: ...434 Administering extended fabrics ...
Страница 460: ...456 Administering ISL trunking ...
Страница 498: ...494 Configuring and monitoring FCIP extension services 556200 Bps 30s avg 491394 Bps lifetime avg ...
Страница 516: ...512 FICON fabrics ...
Страница 526: ...522 Configuring and monitoring FICON Extension Services ...
Страница 540: ...536 Configuring the PID format ...
Страница 544: ...540 Understanding legacy password behavior ...
Страница 546: ...542 Mixed fabric configurations for non merge SANs ...
Страница 550: ...546 Migrating from an MP Router to a 400 MP Router ...
Страница 558: ...554 Inband Management ...
Страница 572: ...568 ...