SV2 Series Safety Shut-off Valves
226
32-00029—02
Address
Type
Valve
Model
Intelligence
Levels
Description
Data
Type
Content
Dec
Hex
418
1A2
Fuel / Air
V2V
Standard
Fuel/Air curve control valve position 5
S16
Control valve position in motor steps recorded during the
fuel/air curve the commissioning.
Position scaled by 4
(i.e. value of 4 is one full step).
419
1A3
Fuel/Air curve control valve position 6
420
1A4
Fuel/Air curve control valve position 7
421
1A5
Fuel/Air curve control valve position 8
422
1A6
Fuel/Air curve control valve position 9
423
1A7
Fuel/Air curve control valve position 10
424
1A8
Fuel/Air curve control valve position 11
425
1A9
Fuel/Air curve control valve position 12
426
1AA
Fuel/Air curve control valve position 13
427
1AB
Fuel/Air curve control valve position 14
428
1AC
Fuel/Air curve control valve position 15
429
1AD
Fuel/Air curve control valve position 16
430
1AE
Fuel/Air curve control valve position 17
431
1AF
Fuel/Air curve control valve position 18
432
1B0
Fuel/Air curve control valve position 19
433
1B1
Fuel/Air curve control valve position 20
434
1B2
Fuel/Air curve control valve position 21
435
1B3
Fuel/Air curve control valve position 23
436
1B4
Fuel/Air curve control valve position 24
467
1D3
Fuel / Air
V2V
Standard
Fault flag 0
U16
0 = FARMOD fatal data (not recoverable)
1 = Flow sensor related faults
2 = Faults related to FARMOD
3 = Stepper motor related faults
4 = FARMOD control valve faults
5 = Light-off related faults
6 = FARMOD EEPROM or flow sensors communication
7 = Control loop
8 = FARMOD data (recoverable)
9 = FAR commissioning
10= FAR curve
11= FARMOD data soft fault
12= New FARMOD detected
468
1D4
Fault flag 1
469
1D5
Fault flag 2
470
1D6
Fault flag 3
615
267
Fue / Air
V2V
Standard
Fan RPM data point 0
S16
User entered combustion fan RPM values during
commissioning (optional)
616
268
Fan RPM data point 1
617
269
Fan RPM data point 2
618
926A
Fan RPM data point 3
619
26B
Fan RPM data point 4
620
26C
Fan RPM data point 5
621
26D
Fan RPM data point 6
622
26E
Fan RPM data point 7
623
26F
Fan RPM data point 8
624
270
Fan RPM data point 9
625
271
Fan RPM data point 10
626
272
Fan RPM data point 11
627
273
Fan RPM data point 12
628
274
Fan RPM data point 13
629
275
Fan RPM data point 14
630
276
Fan RPM data point 15
631
277
Fan RPM data point 16
632