Configuring via the Web Server
Configuring Other I/O
NetAXS-123 Access Control Unit User’s Guide
,
Document 800-05168, Revision B
63
2.7 Configuring Other I/O
This section explains how to configure “other” inputs and outputs on the NetAXS-123
panel. They are called “other” inputs and outputs because you can use them for things
other than door lock/unlock functions. This section explains how to configure these
other inputs and outputs.
2.7.1 Inputs Tab
This tab enables you to configure other input devices on inputs 5 and 6 or other inputs
that have been disassociated from their doors.
When using power supplies with power fail output, the power fail output can be wired
to input 6. When the power supply loses power and switches to battery, input 6 is
activated and a Power Fail alarm is generated. If input 6 is not activated in this
capacity, you can use it for other configurations.
Note:
You can also configure the Power Fail inputs for general use, if you choose not
to wire them for power detection.
The Input tab enables you to:
•
Configure
– Mode
– Shunt Time
– Debounce Time
– Time Zones
– Auto-Relock
Содержание NetAXS-123
Страница 6: ...vi www honeywell com ...
Страница 10: ...NetAXS 123 Access Control Unit User s Guide Document 800 05168 Revision B x ...
Страница 112: ...102 www honeywell com Using WIN PAK with NetAXS 123 Standalone Commands ...
Страница 128: ...118 www honeywell com Monitoring NetAXS 123 Status Monitoring System Status ...
Страница 138: ...128 www honeywell com File Management Generating Reports ...
Страница 162: ...152 www honeywell com Clearing the Cache ...
Страница 166: ...156 www honeywell com ...
Страница 170: ...Index W 160 www honeywell com Door 1 81 Door 2 86 Door 3 91 I O Settings 80 setup 80 standalone commands 96 ...