44
www.honeywell.com
Configuring via the Web Server
Configuring the Doors
Total Num Bits
Lists the total number of bits on the card.
Even Parity
Lists where on the card that even parity is being
observed.
Start Bit
– First bit in the card where even parity begins.
Num Bits
– Number of bits to the right of the start bit,
including the start bit, to include in the even parity check.
Odd Parity
Lists where on the card that odd parity is being observed.
Start Bit
– First bit in the card where odd parity begins.
Num Bits
– Number of bits to the right of the start bit,
including the start bit, to include in the odd parity check.
CID A
Lists where on the card the Card ID A is listed.
Start Bit
– First bit in the card where card ID begins.
Num Bits
– Number of bits to the right of the start bit,
including the start bit, that comprise the card ID.
Most formats require only CID A, and not CID B, C, or
D.
If the Card ID of the card format has multiple parts, CIDs
B, C, and D may be used to specify which parts are to be
concatenated to form the Card ID.
CID B
Lists where on the card the Card ID B is listed.
Start Bit
– First bit in the card where card ID begins.
Num Bits
– Number of bits to the right of the start bit,
including the start bit, that comprise the card ID.
Most formats require only CID A, and not CID B, C, or
D.
CID C
Lists where on the card the Card ID C is listed.
Start Bit
– First bit in the card where card ID begins.
Num Bits
– Number of bits to the right of the start bit,
including the start bit, that comprise the card ID.
Most formats require only CID A, and not CID B, C, or
D.
CID D
Lists where on the card the Card ID D is listed.
Start Bit
– First bit in the card where card ID begins.
Num Bits
– Number of bits to the right of the start bit,
including the start bit, that comprise the card ID.
Most formats require only CID A, and not CID B, C, or
D.
Table 2-7:
Configuration > Doors: > 1 > Reader A > Card Format Fields
Setting
Description
Содержание NetAXS-123
Страница 6: ...vi www honeywell com ...
Страница 10: ...NetAXS 123 Access Control Unit User s Guide Document 800 05168 Revision B x ...
Страница 112: ...102 www honeywell com Using WIN PAK with NetAXS 123 Standalone Commands ...
Страница 128: ...118 www honeywell com Monitoring NetAXS 123 Status Monitoring System Status ...
Страница 138: ...128 www honeywell com File Management Generating Reports ...
Страница 162: ...152 www honeywell com Clearing the Cache ...
Страница 166: ...156 www honeywell com ...
Страница 170: ...Index W 160 www honeywell com Door 1 81 Door 2 86 Door 3 91 I O Settings 80 setup 80 standalone commands 96 ...