Configuring via the Web Server
Configuring the Doors
NetAXS-123 Access Control Unit User’s Guide
,
Document 800-05168, Revision B
53
Steps
: Use the descriptions in
Table 2-9
to configure the Status, Egress, and Tamper
inputs, then click
Submit Changes
:
Table 2-9:
Configuration > Doors: > 1 > Inputs Tab Fields
Setting
Description
Name
Enter a unique name to identify the device.
Mode
Normally Closed
– Specifies that the input’s normal state is
closed (default).
Normally Open
– Specifies that the input’s normal state is open.
Unsupervised
– Specifies that the input’s electrical circuit is
wired in one path without alternative paths supervised by
resistors (default).
Supervised
– Specifies that the input’s electrical circuit is wired
with alternative paths supervised by resistors.
R1 & R2 Values
– Specifies the resistor values being used in the
supervised modes. The drop-down menu lists the following
values: 1K ohms, 2.2K ohms, 4.7K ohms, or 10K ohms. The
default is 2.2K.
Shunt Time
Specifies the amount of time for which the inputs will be
shunted, or de-activated. The maximum number of hours is 1.
When the hour field is blank, the maximum number of minutes
is 59. When 1 is entered in the hour field, the maximum number
of minutes is 45 and the maximum number of seconds is 59. The
sum of all three units comprises the shunt time. Note that you
can express seconds in tenths of a second.
Debounce Time
Specifies the period of time the input must remain in a new state
before generating an alarm. For example, with a 5-second
debounce time selected, if a Normal state is changed to Alarm,
the state must remain in Alarm for five consecutive seconds
before an alarm is generated.
Time Zones
Shunt
– Specifies the time period during which the input will be
ignored.
Disable Interlock
– Specifies the time period during which the
programmed action on this input from another point will be
disabled.
Disable Alarm Msgs
– Specifies the time period during which
Alarm and Normal will not be reported, but Short and Cut will
be reported.
Содержание NetAXS-123
Страница 6: ...vi www honeywell com ...
Страница 10: ...NetAXS 123 Access Control Unit User s Guide Document 800 05168 Revision B x ...
Страница 112: ...102 www honeywell com Using WIN PAK with NetAXS 123 Standalone Commands ...
Страница 128: ...118 www honeywell com Monitoring NetAXS 123 Status Monitoring System Status ...
Страница 138: ...128 www honeywell com File Management Generating Reports ...
Страница 162: ...152 www honeywell com Clearing the Cache ...
Страница 166: ...156 www honeywell com ...
Страница 170: ...Index W 160 www honeywell com Door 1 81 Door 2 86 Door 3 91 I O Settings 80 setup 80 standalone commands 96 ...