Configuring via the Web Server
Configuring the Doors
NetAXS-123 Access Control Unit User’s Guide
,
Document 800-05168, Revision B
39
Anti-Passback
Configures the anti-passback feature. Once configured
under Configuration > System > General screen (see
General Tab
,
page 21
), the user enables the anti-passback
feature on the reader, which requires a valid card for entry
and exit. The card holder must use the card in the proper
IN/OUT sequence--that is, a card swiped at an IN reader
must then be swiped at an OUT reader, or vice versa--a card
swiped at an OUT reader must then be swiped at an IN
reader. If the user's IN/OUT sequence is invalid, then an
anti-passback violation event is generated for the type of
anti-passback chosen (Hard or Soft) and the card holder is
either denied access (Hard) or allowed access (Soft).
Enabled
- Enables the anti-passback feature.
Hard
- Validates IN/OUT status before allowing entry. A
second swipe of the card at the same type of reader
(IN/OUT) causes a Hard anti-passback violation and the
user is denied entry.
Soft
- Validates IN/OUT status before allowing entry. A
second swipe of a card at the same type of reader (IN/OUT)
causes a Soft anti-passback violation but the user is allowed
entry.
Out
- Applies to readers located inside the
anti-passback-controlled area. Card holders use these
readers when attempting to exit the
anti-passback-controlled area.
In
- Applies to readers located outside the
anti-passback-controlled area. Card holders use these
readers when attempting to enter the
anti-passback-controlled area.
Table 2-5:
Configuration > Doors > 1 > Reader A Tab Fields (continued)
Setting
Description
Содержание NetAXS-123
Страница 6: ...vi www honeywell com ...
Страница 10: ...NetAXS 123 Access Control Unit User s Guide Document 800 05168 Revision B x ...
Страница 112: ...102 www honeywell com Using WIN PAK with NetAXS 123 Standalone Commands ...
Страница 128: ...118 www honeywell com Monitoring NetAXS 123 Status Monitoring System Status ...
Страница 138: ...128 www honeywell com File Management Generating Reports ...
Страница 162: ...152 www honeywell com Clearing the Cache ...
Страница 166: ...156 www honeywell com ...
Страница 170: ...Index W 160 www honeywell com Door 1 81 Door 2 86 Door 3 91 I O Settings 80 setup 80 standalone commands 96 ...