Configuring via the Web Server
Configuring the System
Duress Detect
Enabled
- Enables you to trigger an alarm event and, if
configured, pulse an output device in times of duress, such as
when the operator is forced to grant access against his will to
an unauthorized person. Duress requires both a PIN value
and Card number to be recognized, as described below. This
feature is available only when the reader is configured with a
"Card and Pin" access mode (see
Reader A Tab
,
page 36
).
This parameter is set to
Disabled
by default.
When this feature is enabled, a Duress Output option at the
Door's Reader configuration (see
Reader A Tab
,
page 36
) is
also enabled. You then need to assign the selected output--a
Pulse time in Configuration - Other I/O. (See
Outputs Tab
,
page 48
for the output configuration.)
During normal operation, the duress output does nothing. To
energize the output (for example, during a robbery), the card
holder presents his card to a reader that is configured for
Card and PIN access (see
Reader A Tab
,
page 36
). The card
holder then enters a PIN that is either one number higher or
one number lower than the correct PIN. For example, if the
PIN is 2222, the card holder would enter either 2221 or 2223.
Even though the PIN is incorrect, the door will still open
normally, but the duress output pulses and an alarm is
generated. In this way, the card holder notifies others without
detection by the unauthorized person.
Note
: A PIN ending in 0 (for example, 2320) will only trip a
duress output when a 1 is used in place of the 0 (for example,
2321).
Continuous Card Reads
Enabled
– Enables continuous card reading while the output
is being energized. When this option is not enabled, a reader
will not be able to read a second card during the pulsing of
the output caused by the previous card read. This parameter
is set to
Enabled
by default.
Reader LEDs
Identifies the color of a reader LED when a grant is
authorized. When this parameter is enabled, the LED should
be solid red and then turn green after two seconds (by
default).
This parameter is set to
Enabled
by default.
Cardholder ‘Note1’
Specifies any information field you might want to put on a
card. For example, if you enter “Department” here, a field
labeled “Department” appears on the card. The user who
creates the card would then enter the card holder’s
department name. See
Adding New Cards
,
page 56
.
Table 2-3:
System Tools > General Configuration > General Tab Fields (continued)
Parameter
Description
Содержание NetAXS-123
Страница 6: ...vi www honeywell com ...
Страница 10: ...NetAXS 123 Access Control Unit User s Guide Document 800 05168 Revision B x ...
Страница 112: ...102 www honeywell com Using WIN PAK with NetAXS 123 Standalone Commands ...
Страница 128: ...118 www honeywell com Monitoring NetAXS 123 Status Monitoring System Status ...
Страница 138: ...128 www honeywell com File Management Generating Reports ...
Страница 162: ...152 www honeywell com Clearing the Cache ...
Страница 166: ...156 www honeywell com ...
Страница 170: ...Index W 160 www honeywell com Door 1 81 Door 2 86 Door 3 91 I O Settings 80 setup 80 standalone commands 96 ...