Configuring via the Web Server
Configuring the Doors
NetAXS-123 Access Control Unit User’s Guide
,
Document 800-05168, Revision B
51
2.4.4 Inputs Tab
Four inputs are associated with each of the doors on a NetAXS-123 panel:
•
Status – Provides door status information.
•
Egress – Allows the door to open or close normally without generating an
alarm.
•
Tamper A – Reports abnormal handling of the reader device or wiring for
Reader A.
•
Tamper B – Reports abnormal handling of the reader device or wiring for
Reader B.
The Inputs tab enables you to:
•
Define the Status, Egress, and Tamper input modes.
•
Specify the Status, Egress, and Tamper shunt time, or the period of time the
door’s normal state will be ignored.
•
Specify the Status, Egress, and Tamper debounce time, or the period of time
the input must remain in its new state before it is recognized as being in the
new state.
•
Specify the time zones for the Status, Egress, and Tamper inputs.
•
Enable or disable Auto-Relock for the Status inputs.
Click
Inputs
to display the Inputs tab:
Figure 2-17:
Configuration > Doors: > 1 > Inputs Tab > Status
Содержание NetAXS-123
Страница 6: ...vi www honeywell com ...
Страница 10: ...NetAXS 123 Access Control Unit User s Guide Document 800 05168 Revision B x ...
Страница 112: ...102 www honeywell com Using WIN PAK with NetAXS 123 Standalone Commands ...
Страница 128: ...118 www honeywell com Monitoring NetAXS 123 Status Monitoring System Status ...
Страница 138: ...128 www honeywell com File Management Generating Reports ...
Страница 162: ...152 www honeywell com Clearing the Cache ...
Страница 166: ...156 www honeywell com ...
Страница 170: ...Index W 160 www honeywell com Door 1 81 Door 2 86 Door 3 91 I O Settings 80 setup 80 standalone commands 96 ...