Rev. 1.00
326 of 486
July 31, 2018
32-Bit Arm
®
Cortex
®
-M0+ MCU
HT32F50231/HT32F50241
16 Motor Control T
imer (MCTM)
16 Motor Control T
imer (MCTM)
Asymmetric PWM Mode
Asymmetric PWM mode allows two center-aligned PWM signals to be genetated with a
programmable phase shift. While the PWM frequency is determined by the value of the CRR
register, the duty cycle and the phase-shift are determined by the CHxCCR and CHxACR register.
When the counter is counting up, the PWM uses the value in CHxCCR as up-count compare
value. When the counter is into the counting down stage, the PWM uses the value in CHxACR as
down-count compare value. The figure 130 is shown as an example for asymmetric PWM mode in
Center-aligned Counting mode.
Note: Asymmetric PWM mode can only be operated in Center-aligned Counting mode.
2 3 4 5 6 7
0 1
8
5 4 3 2 1 0
7 6
2 3 4 5 6 7
1
8
5 4 3 2 1 0
7 6
2 3 4 5 6 7
1
8
5 4 3 2 1
7 6
CNTR
CHxOREF
CHxOREF
CHxOREF
CHxOREF
PWM center align mode
CRR = 8
CCR = 3, ACR = X
PWM center align mode
CRR = 8
CCR = 5, ACR = X
Asymetric PWM center align mode
CRR = 8
CCR = 3, ACR = 5
Asymetric PWM center align mode
CRR = 8
CCR = 5, ACR = 3
CCR = 3
CCR = 5
CCR = 3
ACR = 5
CCR = 5
ACR = 3
Phase delay =2
CRR = 8
Figure 130. Asymmetric PWM Mode versus Center-aligned Counting Mode