87
Pn No.
Size
Name
Setting range
Setting
Unit
Factory
setting
Available
time
Categor
y
Rema
rks
Pn00A
2 Function
selection
application switch A
0000
~
0044
-
0001
Power
restart
Setup
-
n.
X Stop Method in Case of Gr.2 Alarm
Remarks
0
DB stop or free running stop (stop method is the same as Pn001 =
n.
X).
1
The set torque of Pn406 is used as the maximum torque to
decelerate and stop the motor.
The state after stopping depends on the setting of Pn001 =
n.
X.
2
The set torque of Pn406 is used as the maximum torque to
decelerate and stop the motor.
And then enter a free running state.
3
According to the deceleration time of Pn30A, the motor is
decelerated and stopped.
The state after stopping depends on the setting of Pn001 =
n.
X.
4
According to the deceleration time of Pn30A, the motor will
decelerate and stop, and then enter the free running state.
n.
X
Stop method when forced to stop
Remarks
0
DB stop or free running stop (stop method is the same as Pn001 =
n.
X).
1
The set torque of Pn406 is used as the maximum torque to
decelerate and stop the motor.
The state after stopping depends on the setting of Pn001 =
n.
X.
2
The set torque of Pn406 is used as the maximum torque to
decelerate and stop the motor.
And then enter a free running state.
3
According to the deceleration time of Pn30A, the motor is
decelerated and stopped.
The state after stopping depends on the setting of Pn001 =
n.
X.
4
According to the deceleration time of Pn30A, the motor will
decelerate and stop, and then enter the free running state.
n.
X
Appointment parameters (do not change it)
n.X
Appointment parameters (do not change it)
Pn00B
2 Function
selection
application switch B
0000
~
1121
-
0000
Power
restart
Setup
-
n.
X Operator parameter display selection
Remarks
0
Only set parameters are displayed
1
Display all of the parameters
n.
X
Stop Method in Case of Gr.2 Alarm
Remarks
0
Zero speed stop
1
DB stop or free running stop (stop method is the same as Pn001 =
n.
X).
2
Set the stop method by Pn00A = n.
X.
n.
X
Power Input Selection for Servo Drive with Three-phase Input Specifications Remarks
0
Use three-phase power input.
1
Three-phase input specifications are used for single-phase power
input.
n.X
Appointment parameters (do not change it)
Pn00D
2 Function
selection
application switch D
0000
~
1001
-
0000
Power
restart
Setup
-
n.
X Appointment parameters (do not change it)
n.
X
Appointment parameters (do not change it)
n.
X
Appointment parameters (do not change it)
n.X
Overtravel Warning Check-out Selection
0
No over-travel warning is detected.
1
Check out over-travel warning.
Pn010
2 Axis Address:
(
Modbus/CANopen/USB
)
1
~
127
-
1
Power
restart
Setup
-