64
Steps
Display after operation
Operation
key
Operation
5
Press the S key to display the current offset.
6
Press the UP or DOWN key to adjust and stop the servo motor.
This value is the offset.
7
"donE" will flash and then switch to the display on the left when
the f key is pressed.
8
Press the S key again to return to the display of "FA00b".
8.4.11 Automatic Adjustment of Offset of Motor Current Detection Signal
(
FA00E
)
Please refer to the following contents besides the operation steps
Steps
Display after operation
Operation
key
Operation
1
Press the F key to select the auxiliary function.
2
UP or DOWN key display "FA00E".
3
Press S key, and the display content is shown in the left figure.
4
When the F key is pressed, the offset is automatically adjusted.
After the adjustment is completed, the left display will be
returned after flashing "donE".
5
Press the S key again to return to the display of "FA00E".
8.4.12 Write inhibit setting of parameters
(
FA010
)
Please refer to the following contents besides the operation steps
Steps
Display after operation
Operation
key
Operation
1
Press the F key to select the auxiliary function.
2
UP or DOWN key display "FA010".
3
Press S key, and the display content is shown in the left figure.
4
Press the UP or DOWN key to set to any of the following values.
"P.0000": Allowed to Change [Factory Settings]
"P.0001": no change
5
Press F to confirm the setting. After the setting is completed,
flash "donE" and return to the display on the left.
(Note) "Error" is displayed if it is set to a value other than
"P.0000" and "P.0001".
8.4.13 Displays the motor model (FA011)
Please refer to the following contents besides the operation steps
Steps
Display after operation
Operation
key
Operation
1
Press the F key to select the auxiliary function.