Chapter 2 Selection of Servo Drive
2.1 Ratings and specifications
2.1.1 Rating value
■ Three-phase 220VAC
Model
03A
□□
06A
□□
08A
□□
10A
□□
12A
□□
16A
□□
25A
□□
Continuous Output Current[Arms]
3
6.1
8.5
10
12
16.0
25.0
Instantaneous Max. Output Current [Arms]
10.6
14.1
21.2
24.8
29.7
49.5
63.6
Main Circuit
Power Supply
AC220V
,
-15% to +10%,
50 Hz / 60 Hz
Input Current[Arms]
1.9
(
5.1
)
3.9
(
10.3
)
5.4
(
14.3
)
6.3
(
16.8
)
7.6
10.1
15.7
Control Power Supply
AC220 V
,
-15% to +10%,
50 Hz / 60 Hz
Power Supply Capacity*[kVA]
0.9
(
2.1
)
1.7
(
4.2
)
2.4
(
5.8
)
2.8
(
6.8
)
3.4
4.0
5.9
Regenerative
Resistor
Built-In
Regenerative
Resistor
Resistance[Ω]
——
40
20
20
20
12
20
Capacity[W]
——
80
80
80
80
150
120
Minimum Allowable
External Resistance[Ω]
40
20
15
15
15
15
10
Overvoltage Category
III
■ Three-phase 380VAC
Model No.
15D
18D
24D
35D
Continuous output current [Arms]
15
18
24
35
Maximum instantaneous output current
[Arms]
35.3
44.1
58.9
88.3
Main power
supply
Input power requirements
AC30V
,
-15%
~
+10%,
50 Hz / 60 Hz
Input current [Arms]
8.6
14.5
21.7
31.8
Input control power requirements
DC 24V
,
-10%
~
+10%,
Input power capacity [kVA]
7.1
11.7
14.4
21.9
Regenerative
resistor
Built-in
regenerative
resistor
Resistance
[Ω]
32
23
-
-
Power [W]
150
150
-
-
Minimum allowable external
resistance [Ω]
32
32
23
16
Overvoltage category
III