55
Chapter 8 Panel Display and Use of Panel Operators
8.1 Panel operator
8.1.1 Name and function of panel operator keys
The panel operator consists of a panel display part and panel operator keys.
The panel operator can display the status, perform auxiliary functions, set parameters and monitor the action
of servo drive.
The name and function of the panel operator keys are as follows.
8.1.2 Switching of functions
By switching the functions of the panel
operator, it is possible to display the
operation status, set parameters, switch
operation commands and other functions.
Functions include status display mode, parameter setting mode, monitoring mode and auxiliary function mode.
After pressing the F key, the modes are switched in the order shown in the following figure.
After setting Pn52F (monitoring display when power is turned on), the display content after power is turned on
can be set in monitoring display (non-state display).
Please set the un number to be displayed when the power is turned on in Pn52F.
Pn52F
Monitoring display when power is turned on
Speed
Position
Torque
Setting range
Setting Unit
Factory setting
Effective time
Category
0000
~
0FFF
-
0FFF
Effective
immediately
Setup
When set to 0FFF [factory setting], the status will be displayed when the power is turned on.
Key
Name
Function
Function
key
Toggle basic mode:
Status display, auxiliary functions, parameter
setting and monitoring
Settings
key
Press this key to display the settings and set
values of each parameter, enter the parameter
setting state and clear the alarm.
UP key
Press the UP key to increase the set value
When the auxiliary function mode JOG is
running, it acts as a forward rotation start key.
DOWN
key
Press the DOWN key to decrease the set value
When the auxiliary function mode JOG is
running, it acts as a reverse start key.
Shift key
Press this key to move the selected bit (the
decimal point of the bit flashes) one bit to the
left.
Power ON
Status display mode
Press
down
Press
down
Press
down
Press
down
Press
Press
Press
User parameter mode
Auxiliary function mode
Monitoring mode
Repeat
<sp>