![HNC Electric HSD7-B Series Скачать руководство пользователя страница 71](http://html.mh-extra.com/html/hnc-electric/hsd7-b-series/hsd7-b-series_user-manual_2142012071.webp)
65
Steps
Display after operation
Operation
key
Operation
2
UP or DOWN key display "FA011".
3
Press the S key to display the current motor code. The display
content will be shown in the left figure.
4
Press F key to display the current servo internal parameter 1.
5
Press F key to display the current servo internal parameter 2.
6
Press F key to display the current servo internal parameter 3.
7
Press F key to display the current servo internal parameter 4.
8
Press F key to display the current servo internal parameter 5.
9
Press F key, the current motor capacity is 850W,and the unit is
10W.
10
Press F key, the encoder resolution.
11
Press the S key again to return to the display of "FA011".
8.4.14 Display software version (FA012)
Please refer to the following contents besides the operation steps
Steps
Display after operation
Operation
key
Operation
1
Press the F key to select the auxiliary function.
2
UP or DOWN key display "FA012".
3
Press S to display the servo-driven software version, as shown
in the left figure.
4
Press the F key to display the FPGA version.
5
Press the S key again to return to the display of "FA012".
8.4.15 Single parameter adjustment (FA203)
Please refer to the following contents besides the operation steps
Steps
Display after operation
Operation
key
Operation
1
Press the F key to select the auxiliary function.
2
UP or DOWN key display "FA203".
3