8.3.1 Basic operation of monitoring display
The following description will take Un000 (motor rotation speed) as an example.
Steps Display after operation Operation
key
Operation
1
Press the F key to select the auxiliary function. If the
parameter number does not show UA000, press the
UP or DOWN key to show "UA000".
2
Press S key to display the current motor speed.
When there is no red dot in the lower right corner of
the dual-axis drive, the A-axis data is displayed.
3
When there is a red dot in the lower right corner of
the dual-axis drive, the B-axis data will be displayed.
Press the UP or DOWN key to switch the A axis and
the B axis alternately.
3
Press the S key to return to the display of step 1.
8.3.2 Monitoring of input and output signals (Un005/ Un006)
Use Un005/ Un006 to display the assigned signal status in the segment (LED) of the panel operator.
◆
Display discrimination method
< segment (led) >
The input signal OFF corresponding to the LED number is displayed: the upper segment lights up
The input signal ON corresponding to the LED number is displayed: the lower segment lights up
The distribution table is as follows.
Surveillance
number
Show LED
number
Needle number
Un005
0
IN0
(
CN1-14
)
1
IN1
(
CN1-15
)
2
IN2
(
CN1-16
)
3
IN3
(
CN1-17
)
4
IN4
(
CN1-39
)
5
IN5
(
CN1-40
)
6
IN6
(
CN1-41
)
7
IN7
(
CN1-42
)
Un006
0
OUT0
(
CN1-7, -8
)
1
OUT1
(
CN1-9, -10
)
2
OUT2
(
CN1-11, -12
)
3
OUT3
(
CN1-32, -33
)
4
OUT4
(
CN1-34, -35
)
5
OUT5
(
CN1-36, -37
)
Up: OFF
Down: ON
Show LED number