Replacing
parts
4-3
Hitachi Compute Rack 220S CRU Replacement Guide
When replacing a failed HDD in hot-swap condition, you need the
following conditions.
Configured a disk array with redundancy (RAID1,5,6, or 10)
Disk array is operating in degraded mode.
Or disk array is performing or finishing rebuilding data to a reserve
disk with hot spare function.
Removing an HDD/SSD
1.
Confirm the failed HDD/SSD.
The HDD status LED on the HDD tray lights solid amber.
2.
Push the tab of HDD tray to unlock the HDD/SSD.
3.
Pull the lever open, and then pull out the failed HDD/SSD slightly.
4.
Wait about 30 seconds until the disk motor stops. Then, pull out the
HDD/SSD straight forward.
NOTICE
Do not make an impact on the HDD/SSD. Wait at least 30 seconds
before removing the HDD. Removing the failed HDD during its
motor rotating may damage other HDDs and cause unexpected
failures.
Figure 4-2: Remove a failed HDD (Front side)